Back to Search Start Over

[Application value of domestic single-port robot in nephron sparing surgery].

Authors :
Huang QB
Li Z
Peng C
Guo HQ
Liu GX
Wang XH
Wang GX
Li XH
Xu JN
Wang BJ
Zhang X
Ma X
Source :
Zhonghua yi xue za zhi [Zhonghua Yi Xue Za Zhi] 2024 Sep 10; Vol. 104 (35), pp. 3323-3327.
Publication Year :
2024

Abstract

Objective: To explore the application value of the domestic precision ®single-port robotic system in nephron sparing surgery. Methods: The clinical data of patients with renal masses underwent nephron sparing surgery using the domestic precision ®single-port robotic system at the PLA General Hospital, Gulou Hospital Affiliated to Nanjing University School of Medicine, Zhongnan Hospital of Wuhan University and the First Affiliated Hospital of Nanchang University from September to November 2023 were retrospectively included. Perioperative clinical data, pathological examination results, and postoperative complications were summarized. Results: A total of 12 patients were included, including 8 males and 4 females, with 26-75 (56±16) years. Body mass index (BMI) was (25.1±2.7) kg/m <superscript>2</superscript> . There were 6 cases on the left side and 6 case on the right side. The surgical approach was transabdominal in 9 cases and retroperitoneal in 3 case. The maximum diameter of the lesions was (2.7±0.7) cm, the warm ischemia time [ M ( Q <subscript>1</subscript> , Q <subscript>3</subscript> )] was 19 (15, 26) minutes, the surgical time was 180 (149, 216) minutes, and the intraoperative blood loss was 50 (28, 100) ml. Postoperative visual analogue scale (VAS) was (2.9±1.5) points. Postoperative pathology revealed malignant renal clear cell carcinoma in 9 cases, with nuclear grading of 3 cases for Grade 1, 3 cases for Grade 2, and 3 cases for Grade 3. Eight cases of pathological TNM staging were pT1aN0M0 and 1 case was pT3aN0M0, with no cancer at the resection margin. Three cases showed benign renal vascular smooth muscle lipoma. There were no postoperative blood transfusions and no complications such as fever, urine leakage and poor wound healing. Conclusion: The prliminary experience reveals that the domestic precision ®single-port laparoscopic robotic system has good clinical application value in urological nephron sparing surgery.

Details

Language :
Chinese
ISSN :
0376-2491
Volume :
104
Issue :
35
Database :
MEDLINE
Journal :
Zhonghua yi xue za zhi
Publication Type :
Academic Journal
Accession number :
39266496
Full Text :
https://doi.org/10.3760/cma.j.cn112137-20240123-00171