Back to Search Start Over

Assessment of fluid responsiveness using pulse pressure variation, stroke volume variation, plethysmographic variability index, central venous pressure, and inferior vena cava variation in patients undergoing mechanical ventilation: a systematic review and meta-analysis.

Authors :
Chaves RCF
Barbas CSV
Queiroz VNF
Serpa Neto A
Deliberato RO
Pereira AJ
Timenetsky KT
Silva Júnior JM
Takaoka F
de Backer D
Celi LA
Corrêa TD
Source :
Critical care (London, England) [Crit Care] 2024 Aug 31; Vol. 28 (1), pp. 289. Date of Electronic Publication: 2024 Aug 31.
Publication Year :
2024

Abstract

Importance: Maneuvers assessing fluid responsiveness before an intravascular volume expansion may limit useless fluid administration, which in turn may improve outcomes.<br />Objective: To describe maneuvers for assessing fluid responsiveness in mechanically ventilated patients.<br />Registration: The protocol was registered at PROSPERO: CRD42019146781.<br />Information Sources and Search: PubMed, EMBASE, CINAHL, SCOPUS, and Web of Science were search from inception to 08/08/2023.<br />Study Selection and Data Collection: Prospective and intervention studies were selected.<br />Statistical Analysis: Data for each maneuver were reported individually and data from the five most employed maneuvers were aggregated. A traditional and a Bayesian meta-analysis approach were performed.<br />Results: A total of 69 studies, encompassing 3185 fluid challenges and 2711 patients were analyzed. The prevalence of fluid responsiveness was 49.9%. Pulse pressure variation (PPV) was studied in 40 studies, mean threshold with 95% confidence intervals (95% CI) = 11.5 (10.5-12.4)%, and area under the receiver operating characteristics curve (AUC) with 95% CI was 0.87 (0.84-0.90). Stroke volume variation (SVV) was studied in 24 studies, mean threshold with 95% CI = 12.1 (10.9-13.3)%, and AUC with 95% CI was 0.87 (0.84-0.91). The plethysmographic variability index (PVI) was studied in 17 studies, mean threshold = 13.8 (12.3-15.3)%, and AUC was 0.88 (0.82-0.94). Central venous pressure (CVP) was studied in 12 studies, mean threshold with 95% CI = 9.0 (7.7-10.1) mmHg, and AUC with 95% CI was 0.77 (0.69-0.87). Inferior vena cava variation (∆IVC) was studied in 8 studies, mean threshold = 15.4 (13.3-17.6)%, and AUC with 95% CI was 0.83 (0.78-0.89).<br />Conclusions: Fluid responsiveness can be reliably assessed in adult patients under mechanical ventilation. Among the five maneuvers compared in predicting fluid responsiveness, PPV, SVV, and PVI were superior to CVP and ∆IVC. However, there is no data supporting any of the above mentioned as being the best maneuver. Additionally, other well-established tests, such as the passive leg raising test, end-expiratory occlusion test, and tidal volume challenge, are also reliable.<br /> (© 2024. The Author(s).)

Details

Language :
English
ISSN :
1466-609X
Volume :
28
Issue :
1
Database :
MEDLINE
Journal :
Critical care (London, England)
Publication Type :
Academic Journal
Accession number :
39217370
Full Text :
https://doi.org/10.1186/s13054-024-05078-9