Improved detection of small pulmonary embolism on unenhanced computed tomography using an artificial intelligence-based algorithm - a single centre retrospective study.

Authors :
Hagen F
Vorberg L
Thamm F
Ditt H
Maier A
Brendel JM
Ghibes P
Bongers MN
Krumm P
Nikolaou K
Horger M
Source :
The international journal of cardiovascular imaging [Int J Cardiovasc Imaging] 2024 Aug 28. Date of Electronic Publication: 2024 Aug 28.
Publication Year :
2024
Publisher :
Ahead of Print

Abstract

To preliminarily verify the feasibility of a deep-learning (DL) artificial intelligence (AI) model to localize pulmonary embolism (PE) on unenhanced chest-CT by comparison with pulmonary artery (PA) CT angiography (CTA). In a monocentric study, we retrospectively reviewed 99 oncological patients (median age in years: 64 (range: 28-92 years); percentage of female: 39.4%) who received unenhanced and contrast-enhanced chest CT examinations in one session between January 2020 and October 2022 and who were diagnosed incidentally with PE. Findings in the unenhanced images were correlated with the contrast-enhanced images, which were considered the gold standard for central, segmental and subsegmental PE. The new algorithm was trained and tested based on the 99 unenhanced chest-CT image data sets. Based on them, candidate boxes, which were output by the model, were post-processed by evaluating whether the predicted box intersects with the patient's lung segmentation at any position. The AI-based algorithm proved to have an overall sensitivity of 54.5% for central, of 81.9% for segmental and 80.0% for subsegmental PE if taking nā€‰=ā€‰20 candidate boxes into account. Depending on the localization of the pulmonary embolism, the detection rate for only one box was: 18.1% central, 34.7% segmental and 0.0% subsegmental. The median volume of the clots differed significantly between the three subgroups and was 846.5 mm <superscript>3</superscript> (IQR:591.1-964.8) in central, 201.3 mm <superscript>3</superscript> (IQR:98.3-390.9) in segmental and 110.6 mm <superscript>3</superscript> (IQR:94.3-128.0) in subsegmental PA (pā€‰<ā€‰0.05). The new algorithm proved to have high sensitivity in detecting PE in particular in segmental/subsegmental localization and may guide to decide whether a second contrast enhanced CT is necessary.<br /> (© 2024. The Author(s), under exclusive licence to Springer Nature B.V.)

Details

Language :
English
ISSN :
1875-8312
Database :
MEDLINE
Journal :
The international journal of cardiovascular imaging
Publication Type :
Academic Journal
Accession number :
39196450
Full Text :
https://doi.org/10.1007/s10554-024-03222-8