Quantitative determination of liposomal irinotecan and SN-38 concentrations in plasma samples from children with solid tumors: Use of a cryoprotectant solution to enhance liposome stability.
- Source :
-
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences [J Chromatogr B Analyt Technol Biomed Life Sci] 2024 Sep 15; Vol. 1245, pp. 124273. Date of Electronic Publication: 2024 Aug 14. - Publication Year :
- 2024
-
Abstract
- Preclinical studies have demonstrated that liposomal irinotecan (CPT-11), a topoisomerase I inhibitor, has broad activity against adult cancers, including pancreatic, gastric, colon, lung, glioma, ovarian, and breast cancer. Encapsulation of irinotecan into liposomes can modify its pharmacokinetic properties dramatically. Also, the pharmacokinetic profiles of liposomal drug formulations are not fully understood; thus, bioanalytical methods are needed to separate and quantify nonencapsulated vs. encapsulated concentrations. In this study, two robust, specific, and sensitive LC-MS/MS methods were developed and validated to separate and quantify the nonencapsulated CPT-11 (NE-CPT-11) from the sum-total CPT-11 (T-CPT-11) and its major metabolite, SN-38, in human plasma after intravenous administration of liposomal irinotecan. NE-CPT-11 and SN-38 were separated from plasma samples by using solid-phase extraction, and T-CPT-11 was measured by protein precipitation. The liposomal CPT-11 formulation was unstable during sample storage and handling, resulting in elevated NE-CPT-11 concentration. To improve the stability of liposomal CPT-11, a cryoprotectant solution was added to human plasma samples prior to storage and processing. CPT-11, SN-38, and their respective internal standards, CPT-11-d10 and SN-38-d3, were chromatographically separated on a reversed-phase C <subscript>18</subscript> analytical column. The drugs were detected on a triple quadrupole mass spectrometer in the positive MRM ion mode by monitoring the transitions 587.3 > 124.1 (CPT-11) and 393.0 > 349.1 (SN-38). The calibration curves demonstrated a good fit across the concentration ranges of 10-5000 ng/mL for T-CPT-11, 2.5-250 ng/mL for NE-CPT-11, and 1-500 ng/mL for SN-38. The accuracy and precision were within the acceptable limits, matrix effects were nonsignificant, recoveries were consistent and reproducible, and the analytes were stable under all tested storage conditions. Finally, the LC-MS/MS methods were successfully applied in a phase I clinical pharmacokinetic study of nanoliposomal irinotecan (Onivyde®) in pediatric patients with recurrent solid malignancies or Ewing sarcoma.<br />Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2024 Elsevier B.V. All rights reserved.)
- Subjects :
- Humans
Child
Reproducibility of Results
Limit of Detection
Female
Linear Models
Chromatography, Liquid methods
Male
Adolescent
Irinotecan pharmacokinetics
Irinotecan blood
Liposomes chemistry
Liposomes blood
Tandem Mass Spectrometry methods
Camptothecin analogs & derivatives
Camptothecin pharmacokinetics
Camptothecin blood
Camptothecin administration & dosage
Drug Stability
Neoplasms drug therapy
Neoplasms blood
Subjects
Details
- Language :
- English
- ISSN :
- 1873-376X
- Volume :
- 1245
- Database :
- MEDLINE
- Journal :
- Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
- Publication Type :
- Academic Journal
- Accession number :
- 39146822
- Full Text :
- https://doi.org/10.1016/j.jchromb.2024.124273