Back to Search
Start Over
AI-based volumetric six-tissue body composition quantification from CT cardiac attenuation scans enhances mortality prediction: multicenter study.
- Source :
-
MedRxiv : the preprint server for health sciences [medRxiv] 2024 Aug 01. Date of Electronic Publication: 2024 Aug 01. - Publication Year :
- 2024
-
Abstract
- Background: Computed tomography attenuation correction (CTAC) scans are routinely obtained during cardiac perfusion imaging, but currently only utilized for attenuation correction and visual calcium estimation. We aimed to develop a novel artificial intelligence (AI)-based approach to obtain volumetric measurements of chest body composition from CTAC scans and evaluate these measures for all-cause mortality (ACM) risk stratification.<br />Methods: We applied AI-based segmentation and image-processing techniques on CTAC scans from a large international image-based registry (four sites), to define chest rib cage and multiple tissues. Volumetric measures of bone, skeletal muscle (SM), subcutaneous, intramuscular (IMAT), visceral (VAT), and epicardial (EAT) adipose tissues were quantified between automatically-identified T5 and T11 vertebrae. The independent prognostic value of volumetric attenuation, and indexed volumes were evaluated for predicting ACM, adjusting for established risk factors and 18 other body compositions measures via Cox regression models and Kaplan-Meier curves.<br />Findings: End-to-end processing time was <2 minutes/scan with no user interaction. Of 9918 patients studied, 5451(55%) were male. During median 2.5 years follow-up, 610 (6.2%) patients died. High VAT, EAT and IMAT attenuation were associated with increased ACM risk (adjusted hazard ratio (HR) [95% confidence interval] for VAT: 2.39 [1.92, 2.96], p<0.0001; EAT: 1.55 [1.26, 1.90], p<0.0001; IMAT: 1.30 [1.06, 1.60], p=0.0124). Patients with high bone attenuation were at lower risk of death as compared to subjects with lower bone attenuation (adjusted HR 0.77 [0.62, 0.95], p=0.0159). Likewise, high SM volume index was associated with a lower risk of death (adjusted HR 0.56 [0.44, 0.71], p<0.0001).<br />Interpretations: CTAC scans obtained routinely during cardiac perfusion imaging contain important volumetric body composition biomarkers which can be automatically measured and offer important additional prognostic value.<br />Competing Interests: Declaration of interests RJM received grant support and consulting fees from Pfizer. TDR received research grant support from GE Healthcare and Advanced Accelerator Applications. AJE received speaker fees from Ionetix, consulting fees from W. L. Gore & Associates, authorship fees from Wolters Kluwer Healthcare. AJE served on a scientific advisory board for Canon Medical Systems and received grants from Attralus, Bruker, Canon Medical Systems, Eidos Therapeutics, Intellia Therapeutics, Ionis Pharmaceuticals, Neovasc, Pfizer, Roche Medical Systems, and W. L. Gore & Associates. EJM received grant support from and is a consultant for GE Healthcare. MB was supported by a research award from the Kosciuszko Foundation – The American Centre of Polish Culture. DB and PS participate in software royalties for QPS software at Cedars-Sinai Medical Center. DB served as a consultant for GE Healthcare. PS received research grant support from Siemens Medical Systems, and consulting fees from Synektik S.A. Other Authors declared no competing interests.
Details
- Language :
- English
- Database :
- MEDLINE
- Journal :
- MedRxiv : the preprint server for health sciences
- Publication Type :
- Academic Journal
- Accession number :
- 39132480
- Full Text :
- https://doi.org/10.1101/2024.07.30.24311224