Performance evaluation and characterization of pre-analytical effects by sample types and storage conditions on tumor marker measurement by the point-of-care test platform Ichroma TM II.
- Source :
-
Clinica chimica acta; international journal of clinical chemistry [Clin Chim Acta] 2024 Sep 15; Vol. 563, pp. 119902. Date of Electronic Publication: 2024 Aug 05. - Publication Year :
- 2024
-
Abstract
- Tumor markers should be measured regularly and accurately to prevent, diagnose, and monitor cancers efficiently. We aimed to characterize the pre-analytical factors effecting on the analytical performance of point-of-care test (POCT) platform Ichroma <superscript>TM</superscript> II (Boditech Med Inc., Gangwon-do, Korea) for alpha-fetoprotein (AFP), carcinoembryonic antigen (CEA), and prostate specific antigen (PSA) and evaluate their consequences in clinical practice. Based on comprehensive evaluation for the analytical performance of Ichroma <superscript>TM</superscript> II including precision, linearity, and method comparison performed according to CLSI guidelines, pre-analytical factors of sample types and conditions were extensively analyzed. A total of five sample types [serum, plasma (PL) and whole blood (WB) from EDTA tube, PL and WB from sodium heparin tube] from 40 patients were used for comparing among specimen types. Additionally, stability was assessed up to 21 h at room temperature, refrigerated for 8 days, and frozen for 16 weeks by using 4 levels of pooled patient samples which were measured in triplicate. Precision, linearity and correlation with central laboratory analyzers observed in all three tumor markers were within acceptable criteria. However, variable degrees of percent deviations were observed according to sample type and storage conditions. Only EDTA PL samples presented clinically acceptable percentage biases for all three tumor markers when stored at room temperature or refrigerated condition. Positive bias of CEA and PSA in storage duration until 16 weeks were observed when stored in frozen condition. While Ichroma <superscript>TM</superscript> II showed an adequate analytical performance as a POCT platform with simple operating procedures for the measurement of tumor markers, clinical laboratories should be aware of stability issues when different types of blood specimens are practically utilized.<br />Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2024 The Authors. Published by Elsevier B.V. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1873-3492
- Volume :
- 563
- Database :
- MEDLINE
- Journal :
- Clinica chimica acta; international journal of clinical chemistry
- Publication Type :
- Academic Journal
- Accession number :
- 39111647
- Full Text :
- https://doi.org/10.1016/j.cca.2024.119902