Back to Search Start Over

Transapical transcatheter mitral valve replacement for mitral valve disease: an Iberian experience.

Authors :
Gutiérrez-Ortiz E
Cobiella J
Muñoz-Guijosa C
Teles RC
Estévez-Loureiro R
Moñivas V
Regueiro A
Blasco-Turrión S
Mahía P
Figuereo Beltre D
Freitas P
Piñón M
Amat-Santos IJ
Julià Amill I
Nolasco T
Pereda D
Martín López C
Nombela-Franco L
Source :
Revista espanola de cardiologia (English ed.) [Rev Esp Cardiol (Engl Ed)] 2024 Jul 26. Date of Electronic Publication: 2024 Jul 26.
Publication Year :
2024
Publisher :
Ahead of Print

Abstract

Introduction and Objectives: Transcatheter mitral valve replacement (TMVR) is an emerging treatment alternative for mitral valve (MV) disease in patients who were ineligible for surgical intervention or edge-to-edge repair. This study aimed to assess the short- and mid-term outcomes of this procedure.<br />Methods: We conducted a prospective registry to include the initial experience with symptomatic, consecutive patients who underwent TMVR using the transapical Tendyne system at 7 centers in the Iberian Peninsula. Baseline clinical and imaging data, periprocedural information, and follow-up assessments were collected at 1 month and 1 year.<br />Results: A total of 40 patients (mean age 78.5 years [76-82], 47,5% males) underwent TMVR. The majority had significant surgical risk, comorbidities, and advanced functional class. All patients had significant mitral regurgitation (MR), except for 2 with severe stenosis. Previous MV intervention and off-label indication for the procedure were present in 4 (10.0%) and 8 (20.0%) patients, respectively. Technical success was recorded in 100%, device success in 95.0%, and procedural success in 85.0% at 30-day. All-cause mortality was 2.5% and 17.5% at the 1-month and 1-year follow-up, respectively. MR reduction (≤ 1) and functional class improvement (NYHA I-II) were observed at 1 year in 93.9% and 87.9% of survivors, respectively.<br />Conclusions: Treatment with TMVR produced enduring resolution of MV disease and notable functional enhancement at 1 year of follow-up. The procedure demonstrated a satisfactory early safety profile, although 1-year mortality remained relatively high in this high-risk population.<br /> (Copyright © 2024 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.)

Details

Language :
English; Spanish; Castilian
ISSN :
1885-5857
Database :
MEDLINE
Journal :
Revista espanola de cardiologia (English ed.)
Publication Type :
Academic Journal
Accession number :
39068987
Full Text :
https://doi.org/10.1016/j.rec.2024.07.004