Back to Search
Start Over
Extended nnU-Net for Brain Metastasis Detection and Segmentation in Contrast-Enhanced Magnetic Resonance Imaging With a Large Multi-Institutional Data Set.
- Source :
-
International journal of radiation oncology, biology, physics [Int J Radiat Oncol Biol Phys] 2024 Jul 25. Date of Electronic Publication: 2024 Jul 25. - Publication Year :
- 2024
- Publisher :
- Ahead of Print
-
Abstract
- Purpose: The purpose of this study was to investigate an extended self-adapting nnU-Net framework for detecting and segmenting brain metastases (BM) on magnetic resonance imaging (MRI).<br />Methods and Materials: Six different nnU-Net systems with adaptive data sampling, adaptive Dice loss, or different patch/batch sizes were trained and tested for detecting and segmenting intraparenchymal BM with a size ≥2 mm on 3 Dimensional (3D) post-Gd T1-weighted MRI volumes using 2092 patients from 7 institutions (1712, 195, and 185 patients for training, validation, and testing, respectively). Gross tumor volumes of BM delineated by physicians for stereotactic radiosurgery were collected retrospectively and curated at each institute. Additional centralized data curation was carried out to create gross tumor volumes of uncontoured BM by 2 radiologists to improve the accuracy of ground truth. The training data set was augmented with synthetic BMs of 1025 MRI volumes using a 3D generative pipeline. BM detection was evaluated by lesion-level sensitivity and false-positive (FP) rate. BM segmentation was assessed by lesion-level Dice similarity coefficient, 95-percentile Hausdorff distance, and average Hausdorff distance (HD). The performances were assessed across different BM sizes. Additional testing was performed using a second data set of 206 patients.<br />Results: Of the 6 nnU-Net systems, the nnU-Net with adaptive Dice loss achieved the best detection and segmentation performance on the first testing data set. At an FP rate of 0.65 ± 1.17, overall sensitivity was 0.904 for all sizes of BM, 0.966 for BM ≥0.1 cm <superscript>3</superscript> , and 0.824 for BM <0.1 cm <superscript>3</superscript> . Mean values of Dice similarity coefficient, 95-percentile Hausdorff distance, and average HD of all detected BMs were 0.758, 1.45, and 0.23 mm, respectively. Performances on the second testing data set achieved a sensitivity of 0.907 at an FP rate of 0.57 ± 0.85 for all BM sizes, and an average HD of 0.33 mm for all detected BM.<br />Conclusions: Our proposed extension of the self-configuring nnU-Net framework substantially improved small BM detection sensitivity while maintaining a controlled FP rate. Clinical utility of the extended nnU-Net model for assisting early BM detection and stereotactic radiosurgery planning will be investigated.<br /> (Copyright © 2024 Elsevier Inc. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1879-355X
- Database :
- MEDLINE
- Journal :
- International journal of radiation oncology, biology, physics
- Publication Type :
- Academic Journal
- Accession number :
- 39059508
- Full Text :
- https://doi.org/10.1016/j.ijrobp.2024.07.2318