Back to Search Start Over

Reproducibility of LPS-Induced ex vivo Cytokine Response of Healthy Volunteers Using a Whole Blood Assay.

Authors :
Jorda A
Eberl S
Nussbaumer-Pröll A
Sarhan M
Weber M
Tegrovsky LE
Wahrmann M
Al Jalali V
Bergmann F
Pracher L
Leutzendorff A
Farlik M
Jilma B
Zeitlinger M
Source :
Journal of inflammation research [J Inflamm Res] 2024 Jul 17; Vol. 17, pp. 4781-4790. Date of Electronic Publication: 2024 Jul 17 (Print Publication: 2024).
Publication Year :
2024

Abstract

Introduction: Lipopolysaccharide (LPS) stimulation of human whole blood ex vivo has been widely used to investigate human innate immune responses. However, there are uncertainties regarding the reproducibility and reliability of this assay.<br />Methods: In this prospective, single-center study, cytokine responses (interleukin 8, interferon-α, interferon-γ, interleukin 10, interleukin 1-β, interleukin 6, and tumor necrosis factor-α) to ex vivo whole blood LPS stimulation were assessed in 12 healthy volunteers. Cytokine levels were measured at 0, 2, and 4 h using a multiplex immunoassay (Luminex <superscript>®</superscript> ). Stimulation was repeated after six weeks. We examined reproducibility across technical and biological replicates at baseline and between repeated experiments after 6 weeks based on the area under the curve (AUC) of the individual cytokines using Pearson's correlation coefficient and the mean coefficient of variation.<br />Results: The lowest mean coefficients of variation were observed for the technical replicates (5.4 to 9.2%), followed by the biological replicates (8.1 to 24.8%), and the repeated experiments after 6 weeks (17 to 31.2%). Between the baseline and 6-week AUCs, the following Pearson correlation coefficients R were observed: interleukin 10, 0.97; interferon-α, 0.84; interleukin 1-β, 0.83; interleukin 8, 0.79; interleukin 6, 0.73; interferon-γ, 0.73; and tumor necrosis factor-α, 0.63.<br />Discussion: The level of agreement between the baseline and week-6 cytokine response to ex vivo LPS stimulation was high across the seven cytokines analyzed. While interleukin 10 exhibited the lowest level of variability over time, tumor necrosis factor-α showed the highest variability in repeated experiments, which should be considered in the design and interpretation of future studies.<br />Competing Interests: The authors report no conflicts of interest in this work.<br /> (© 2024 Jorda et al.)

Details

Language :
English
ISSN :
1178-7031
Volume :
17
Database :
MEDLINE
Journal :
Journal of inflammation research
Publication Type :
Academic Journal
Accession number :
39051050
Full Text :
https://doi.org/10.2147/JIR.S459999