Back to Search Start Over

Development of UPLC-MS/MS method for the simultaneous quantification of valproic acid and phenytoin in human plasma and application to study pharmacokinetic interaction in epilepsy patients.

Authors :
Nguyen ST
Ho DN
Huynh TAH
Nguyen HTT
Thi Ly NK
Van Le M
Minh Chau Do TV
Source :
Heliyon [Heliyon] 2024 Jun 25; Vol. 10 (13), pp. e33630. Date of Electronic Publication: 2024 Jun 25 (Print Publication: 2024).
Publication Year :
2024

Abstract

Valproic acid and phenytoin are two prevalent antiepileptic medications known for their narrow indices and propensity for cardiovascular and respiratory system toxicity. Therefore, therapeutic drug monitoring (TDM) of valproic acid (VAL) and phenytoin (PHE) concentrations in patient plasma is extremely beneficial for improving clinical choices, avoiding adverse reactions, and optimizing treatment for individual patients. In this study, a rapid and sensitive ultra-performance liquid chromatographic tandem mass spectrometer (UPLC-MS/MS) method was developed and validated for the simultaneous quantitative determination of valproic acid (VAL) and phenytoin (PHE) in human plasma. Negative electron spray ionization (ESI-) mode with selective ion recording (SIR) was employed to determine the transitions of m / z 142.98 and m / z 250.93 for VAL and PHE, respectively. The internal standard (IS) betamethasone (BETA) was ionized using positive electron spray ionization (ESI+) and detected by multi-reaction monitoring (MRM) mode to obtain precursor ions and specific fragment ions for quantification, and the MRM transition was chosen to be m / z 393.17 → 355.16. The separation was performed using a Phenomenex Synergi Hydro-RP (4 μm, 250 × 4.6 mm, I.D.) with an isocratic mobile phase consisting of acetonitrile - water (75:25, v/v) at a flow rate of 0.8 mL/min. The column temperature was maintained at 25 °C. The lower limit of quantification of VAL and PHE was 3.6 μg/mL and 0.72 μg/mL, respectively, which resulted in a recovery of more than 85 % for most analytes. According to US-FDA bioanalytical technique validation, the specificity, intra- and inter-day precision and accuracy, matrix effect, carryover, dilution, and stability of all analytes were within acceptable ranges. This analytical method was successful in evaluating the levels of valproic acid and phenytoin in human plasma from epileptic patients.<br />Competing Interests: The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (© 2024 The Authors.)

Details

Language :
English
ISSN :
2405-8440
Volume :
10
Issue :
13
Database :
MEDLINE
Journal :
Heliyon
Publication Type :
Academic Journal
Accession number :
39040279
Full Text :
https://doi.org/10.1016/j.heliyon.2024.e33630