Back to Search Start Over

Effects of the Irrigation Needle Design on Root Canal Disinfection and Cleaning.

Authors :
Baasch A
Campello AF
Rodrigues RCV
Alves FRF
Voigt DD
Mdala I
Perez R
Brasil SC
Rôças IN
Siqueira JF Jr
Source :
Journal of endodontics [J Endod] 2024 Oct; Vol. 50 (10), pp. 1463-1471. Date of Electronic Publication: 2024 Jul 17.
Publication Year :
2024

Abstract

Introduction: This ex vivo study evaluated the disinfecting and cleaning effects of root canal preparation using sodium hypochlorite irrigation with 3 different needle designs.<br />Methods: Mesial roots from extracted mandibular molars with Vertucci class II configuration were anatomically matched based on micro-computed tomography (micro-CT) analyses and distributed into 3 groups (n = 18/group). The canals were contaminated with a mixed bacterial culture for 30 days and then subjected to preparation using 2.5% sodium hypochlorite irrigation with open-ended flat needle (3 mm short of the working length - WL), closed-ended side-vented irrigation needle (1 mm short of the WL), or a closed-ended plastic needle with 2 lateral outlets (TruNatomy) (1 mm short of the WL). Bacteriological samples were taken from the canals before (S1) and after preparation (S2). After another micro-CT scan, the roots were sectioned and samples were also taken from the apical canal segment (S3). Bacterial reduction was assessed by quantitative real-time polymerase chain reaction. The amount of accumulated hard tissue debris was evaluated by micro-CT.<br />Results: A substantial reduction in bacterial counts was observed in all 3 groups when comparing S1 with S2 (99.95%, 98.93%, and 98.90% in the open-ended, closed-ended, and TruNatomy needle groups, respectively) (P < .01). No significant differences were observed between groups for bacterial reduction in the full and apical canal (P > .05). There were no intergroup differences in the amount of accumulated hard tissue debris either (P > .05). The open-ended needle group showed significantly more specimens with quantitative real-time polymerase chain reaction negative results for bacteria in S3 than TruNatomy (P < .05).<br />Conclusion: When used up to an appropriate insertion depth, the 3 needle types result in similar antibacterial and cleaning performance, provided variables such as needle size and irrigant type, volume and flow rate are controlled. Exclusive analysis of the apical segment, including the isthmus, revealed that the open-ended needle yielded more cases negative for bacteria.<br /> (Copyright © 2024 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1878-3554
Volume :
50
Issue :
10
Database :
MEDLINE
Journal :
Journal of endodontics
Publication Type :
Academic Journal
Accession number :
39029891
Full Text :
https://doi.org/10.1016/j.joen.2024.07.006