Back to Search
Start Over
Carotid artery stenting with flow inversion cerebral protection and MicroNet-covered stent.
- Source :
-
The Journal of cardiovascular surgery [J Cardiovasc Surg (Torino)] 2024 Jun; Vol. 65 (3), pp. 221-230. - Publication Year :
- 2024
-
Abstract
- Background: The study aims to evaluate the association of proximal flow-inversion cerebral protection and MicroNet-covered CGuard stents in reducing early and late embolic events in carotid artery stenting procedures.<br />Methods: From 2018 to 2023, we performed 204 procedures in 180 patients with flow inversion cerebral protection and CGuard stents at the Vascular Surgery Unit of Sant'Eugenio Hospital in Rome. Cerebral protection was achieved with a Flow-Gate2 catheter connected to a peripheral vein. The tip balloon is inflated in the CCA to obtain an effective endoclamping, the pressure difference between the carotid bifurcation and the venous compartment ensures a constant back flow with wash-out in the venous compartment. Inclusion criteria were: life expectancy of >12 months, target lesions indicating treatment according to ESVS Guidelines, increased surgical risk due to comorbidities or anatomic issues. ECD follow-up was performed immediately postoperatively, at 30 days, 6 and 12 months, and subsequently annually.<br />Results: The treatment protocol was successfully implemented in 99% of cases. No major strokes occurred, while one minor stroke (0.5%) occurred within 8 hours of the procedure, regressing in the following months. One perioperative death (0.5%) due to cerebral hemorrhage occurred three hours after the procedure. All patients remained asymptomatic, with no short or medium-term neurological score deterioration. One hemodynamically significant restenosis (0.5%) was detected at the 6-month follow-up. All patients completed the 6 months follow-up, though 6 (3%) were lost at the 12-month appointment.<br />Conclusions: Our prospective monocentric study has demonstrated the effectiveness and safety of the FlowGate2 flow inversion cerebral protection system in association with MicroNet covered CGuard stent.
- Subjects :
- Humans
Female
Male
Aged
Treatment Outcome
Time Factors
Cerebrovascular Circulation
Middle Aged
Aged, 80 and over
Risk Factors
Rome
Angioplasty, Balloon adverse effects
Angioplasty, Balloon instrumentation
Intracranial Embolism prevention & control
Intracranial Embolism etiology
Prospective Studies
Stents
Carotid Stenosis complications
Carotid Stenosis physiopathology
Carotid Stenosis surgery
Carotid Stenosis diagnostic imaging
Carotid Stenosis therapy
Prosthesis Design
Embolic Protection Devices
Subjects
Details
- Language :
- English
- ISSN :
- 1827-191X
- Volume :
- 65
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- The Journal of cardiovascular surgery
- Publication Type :
- Academic Journal
- Accession number :
- 39007555
- Full Text :
- https://doi.org/10.23736/S0021-9509.24.13067-4