Back to Search Start Over

Factors associated with carbon dioxide transfer in an experimental model of severe acute kidney injury and hypoventilation during high bicarbonate continuous renal replacement therapy and oxygenation membrane support.

Authors :
Santos YAPD
Cardozo Junior LCM
Mendes PV
Besen BAMP
Park M
Source :
Critical care science [Crit Care Sci] 2024 Jul 08; Vol. 36, pp. e20240005en. Date of Electronic Publication: 2024 Jul 08 (Print Publication: 2024).
Publication Year :
2024

Abstract

Objective: To investigate the factors influencing carbon dioxide transfer in a system that integrates an oxygenation membrane in series with high-bicarbonate continuous veno-venous hemodialysis in hypercapnic animals.<br />Methods: In an experimental setting, we induced severe acute kidney injury and hypercapnia in five female Landrace pigs. Subsequently, we initiated high (40mEq/L) bicarbonate continuous veno-venous hemodialysis with an oxygenation membrane in series to maintain a pH above 7.25. At intervals of 1 hour, 6 hours, and 12 hours following the initiation of continuous veno-venous hemodialysis, we performed standardized sweep gas flow titration to quantify carbon dioxide transfer. We evaluated factors associated with carbon dioxide transfer through the membrane lung with a mixed linear model.<br />Results: A total of 20 sweep gas flow titration procedures were conducted, yielding 84 measurements of carbon dioxide transfer. Multivariate analysis revealed associations among the following (coefficients ± standard errors): core temperature (+7.8 ± 1.6 °C, p < 0.001), premembrane partial pressure of carbon dioxide (+0.2 ± 0.1/mmHg, p < 0.001), hemoglobin level (+3.5 ± 0.6/g/dL, p < 0.001), sweep gas flow (+6.2 ± 0.2/L/minute, p < 0.001), and arterial oxygen saturation (-0.5 ± 0.2%, p = 0.019). Among these variables, and within the physiological ranges evaluated, sweep gas flow was the primary modifiable factor influencing the efficacy of low-blood-flow carbon dioxide removal.<br />Conclusion: Sweep gas flow is the main carbon dioxide removal-related variable during continuous veno-venous hemodialysis with a high bicarbonate level coupled with an oxygenator. Other carbon dioxide transfer modulating variables included the hemoglobin level, arterial oxygen saturation, partial pressure of carbon dioxide and core temperature. These results should be interpreted as exploratory to inform other well-designed experimental or clinical studies.

Details

Language :
English; Portuguese
ISSN :
2965-2774
Volume :
36
Database :
MEDLINE
Journal :
Critical care science
Publication Type :
Academic Journal
Accession number :
38985048
Full Text :
https://doi.org/10.62675/2965-2774.20240005-en