Back to Search Start Over

Clipless internal mammary artery harvesting for minimally invasive coronary artery bypass grafting using the shear-tip harmonic scalpel.

Authors :
Jung YC
Chong Y
Kang MW
Han SJ
Cho HJ
Park SJ
Shim MS
Source :
Journal of thoracic disease [J Thorac Dis] 2024 Jun 30; Vol. 16 (6), pp. 3711-3721. Date of Electronic Publication: 2024 Jun 13.
Publication Year :
2024

Abstract

Background: The internal mammary artery (IMA) is the most commonly used graft in coronary artery bypass grafting (CABG) because of its superior long-term patency rate. However, its small diameter poses challenges in handling, and any vascular damage that may occur during harvesting can significantly affect surgical outcomes. The primary focus during IMA harvesting is to ensure safe and effective hemostasis without direct vascular injury, while ensuring secure and reliable ligation of the vascular branches. Various methods using multiple surgical instruments have been used for this purpose. Unlike traditional instruments, the shear-tip Harmonic scalpel offers more precise vessel branching control, while minimizing damage to surrounding tissues. In this study, we assessed the utility of the shear-tip Harmonic scalpel in patients undergoing minimally invasive coronary artery bypass grafting (MICABG).<br />Methods: From April 2019 to May 2023, a total of 40 patients underwent MICABG. The IMA was harvested using the shear-tip Harmonic scalpel with a clipless skeletonized technique. In this cohort, 5 patients underwent complete endoscopic harvesting, while 34 patients underwent direct visualization harvesting through minimal thoracotomy. Graft patency was assessed by measuring a Doppler flowmeter in the bypass conduit.<br />Results: Successful graft patency was achieved in all patients. The mean duration of IMA harvesting was 87 min. In total, 38 of the 40 patients underwent MICABG without the need for cardiopulmonary bypass, ensuring a stable procedure. There were no graft-related events or complications observed in any of the patients, and all were discharged without any issues. During a median follow-up period of 15.2 months, only one patient experienced graft occlusion necessitating intervention.<br />Conclusions: The utilization of shear-tip Harmonic scalpel for IMA harvesting in MICABG is feasible and yields stable early results.<br />Competing Interests: Conflicts of Interest: All authors have completed the ICMJE uniform disclosure form (available at https://jtd.amegroups.com/article/view/10.21037/jtd-23-1810/coif). The authors have no conflicts of interest to declare.<br /> (2024 Journal of Thoracic Disease. All rights reserved.)

Details

Language :
English
ISSN :
2072-1439
Volume :
16
Issue :
6
Database :
MEDLINE
Journal :
Journal of thoracic disease
Publication Type :
Academic Journal
Accession number :
38983142
Full Text :
https://doi.org/10.21037/jtd-23-1810