Back to Search
Start Over
In-vivo high-frequency quantitative ultrasound-derived parameters of the anterior sclera correlated with level of myopia and presence of staphyloma.
- Source :
-
Clinical & experimental ophthalmology [Clin Exp Ophthalmol] 2024 Nov; Vol. 52 (8), pp. 840-852. Date of Electronic Publication: 2024 Jul 04. - Publication Year :
- 2024
-
Abstract
- Background: A high-frequency point-of-care (POC) ultrasound instrument was used to evaluate the microstructural and biomechanical properties of the anterior sclera in vivo using parameters computed from quantitative ultrasound (QUS) methods.<br />Methods: In this cross-sectional study, both eyes of 85 enrolled patients were scanned with the POC instrument and ultrasound data were processed to obtain QUS parameters. Pearson correlation and multi-linear regression were used to identify relationships between QUS parameters and refractive error (RE) or axial length. After categorising eyes based on RE, binary support vector machine (SVM) classifiers were trained using the QUS or ophthalmic parameters (anterior chamber depth, central corneal thickness, corneal power, and intraocular pressure) to classify each eye. Classifier performance was evaluated by computing the area under the receiver-operating characteristic curve (AUC).<br />Results: Individual QUS parameters correlated with RE and axial length (p < 0.05). Multi-linear regression revealed significant correlation between the set of QUS parameters and both RE (R = 0.49, p < 0.001) and axial length (R = 0.46, p = 0.001). Classifiers trained with QUS parameters achieved higher AUC (𝑝 = 0.06) for identifying myopic eyes (AUC = 0.71) compared to classifiers trained with ophthalmic parameters (AUC = 0.63). QUS-based classifiers attained the highest AUC when identifying highly myopic eyes (AUC = 0.77).<br />Conclusions: QUS parameters correlate with progressing myopia and may be indicative of myopia-induced microstructural and biomechanical changes in the anterior sclera. These methods may provide critical clinical information complementary to standard ophthalmic measurements for predicting myopia progression and risk assessment for posterior staphyloma formation.<br /> (© 2024 Royal Australian and New Zealand College of Ophthalmologists.)
- Subjects :
- Humans
Male
Cross-Sectional Studies
Female
Middle Aged
Adult
Aged
Intraocular Pressure physiology
Dilatation, Pathologic
Young Adult
Point-of-Care Systems
Refraction, Ocular physiology
Sclera diagnostic imaging
Ultrasonography methods
Axial Length, Eye diagnostic imaging
Axial Length, Eye pathology
Myopia physiopathology
Myopia diagnostic imaging
Myopia diagnosis
Scleral Diseases diagnosis
Scleral Diseases diagnostic imaging
Scleral Diseases physiopathology
ROC Curve
Subjects
Details
- Language :
- English
- ISSN :
- 1442-9071
- Volume :
- 52
- Issue :
- 8
- Database :
- MEDLINE
- Journal :
- Clinical & experimental ophthalmology
- Publication Type :
- Academic Journal
- Accession number :
- 38964827
- Full Text :
- https://doi.org/10.1111/ceo.14415