Self-Sampling by Adolescents at Home: Assessment of the Feasibility to Successfully Collect Blood Microsamples by Inexperienced Individuals.

Authors :
Boffel L
Van Mensel A
Pauwels J
Den Hond E
Bessems J
Van Uytfanghe K
Stove CP
Source :
The AAPS journal [AAPS J] 2024 Jul 02; Vol. 26 (4), pp. 75. Date of Electronic Publication: 2024 Jul 02.
Publication Year :
2024

Abstract

Blood microsampling has increasingly attracted interest in the past decades as a more patient-centric sampling approach, offering the possibility to collect a minimal volume of blood following a finger or arm prick at home. In addition to conventional dried blood spots (DBS), many different devices allowing self-sampling of blood have become available. Obviously, the success of home-sampling can only be assured when (inexperienced) users collect samples of good quality. Therefore, the feasibility of six different microsampling devices to collect capillary blood by inexperienced adolescents at home was evaluated. Participants (nā€‰=ā€‰95) were randomly assigned to collect blood (dried or liquid) at different time points using four of six different self-sampling devices (i.e., DBS, Mitra volumetric absorptive microsampling (VAMS), Capitainer B, Tasso M20, Minicollect tube and Tasso <superscript>+</superscript> serum separator tube (SST)). The quality of the samples was visually inspected and analytically determined. Moreover, the participants' satisfaction was assessed via questionnaires. Although a majority succeeded based on the visual inspection, the success rate differed largely between the different devices. In general, the lowest success rate was obtained for the Minicollect tubes, although there is an opportunity and need for improvement for the other self-sampling devices as well. Hence, this also emphasizes the importance to assess the quality of samples collected by the target population prior to study initiation. In addition, visual classification by a trained individual was confirmed based on assessment of the analytical variability between replicates. Finally, self-sampling at home was overall (very) positively received by the participants.<br /> (© 2024. The Author(s), under exclusive licence to American Association of Pharmaceutical Scientists.)

Details

Language :
English
ISSN :
1550-7416
Volume :
26
Issue :
4
Database :
MEDLINE
Journal :
The AAPS journal
Publication Type :
Academic Journal
Accession number :
38955903
Full Text :
https://doi.org/10.1208/s12248-024-00947-1