Back to Search
Start Over
Depth resolved pencil beam radiography using AI - a proof of principle study.
- Source :
-
Journal of instrumentation : an IOP and SISSA journal [J Instrum] 2022 Jun; Vol. 17 (6). Date of Electronic Publication: 2022 Jun 07. - Publication Year :
- 2022
-
Abstract
- Aims: Clinical radiographic imaging is seated upon the principle of differential keV photon transmission through an object. At clinical x-ray energies the scattering of photons causes signal noise and is utilized solely for transmission measurements. However, scatter - particularly Compton scatter, is characterizable. In this work we hypothesized that modern radiation sources and detectors paired with deep learning techniques can use scattered photon information constructively to resolve superimposed attenuators in planar x-ray imaging.<br />Methods: We simulated a monoenergetic x-ray imaging system consisting of a pencil beam x-ray source directed at an imaging target positioned in front of a high spatial- and energy-resolution detector array. The setup maximizes information capture of transmitted photons by measuring off-axis scatter location and energy. The signal was analyzed by a convolutional neural network, and a description of scattering material along the axis of the beam was derived. The system was virtually designed/tested using Monte Carlo processing of simple phantoms consisting of 10 pseudo-randomly stacked air/bone/water materials, and the network was trained by solving a classification problem.<br />Results: From our simulations we were able to resolve traversed material depth information to a high degree, within our simple imaging task. The average accuracy of the material identification along the beam was 0.91±0.01, with slightly higher accuracy towards the entrance/exit peripheral surfaces of the object. The average sensitivity and specificity was 0.91 and 0.95, respectively.<br />Conclusions: Our work provides proof of principle that deep learning techniques can be used to analyze scattered photon patterns which can constructively contribute to the information content in radiography, here used to infer depth information in a traditional 2D planar setup. This principle, and our results, demonstrate that the information in Compton scattered photons may provide a basis for further development. The work was limited by simple testing scenarios and without yet integrating complexities or optimizations. The ability to scale performance to the clinic remains unexplored and requires further study.
Details
- Language :
- English
- ISSN :
- 1748-0221
- Volume :
- 17
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- Journal of instrumentation : an IOP and SISSA journal
- Publication Type :
- Academic Journal
- Accession number :
- 38938475
- Full Text :
- https://doi.org/10.1088/1748-0221/17/06/p06012