Back to Search Start Over

Myocardial Blood Flow by Magnetic Resonance in Patients With Suspected Coronary Stenosis: Comparison to PET and Invasive Physiology.

Authors :
Rasmussen LD
Murphy T
Milidonis X
Eftekhari A
Karim SR
Westra J
Dahl JN
Isaksen C
Brix L
Ejlersen JA
Nyegaard M
Johansen JK
Søndergaard HM
Mortensen J
Gormsen LC
Christiansen EH
Chiribiri A
Petersen SE
Bøttcher M
Winther S
Source :
Circulation. Cardiovascular imaging [Circ Cardiovasc Imaging] 2024 Jun; Vol. 17 (6), pp. e016635. Date of Electronic Publication: 2024 Jun 18.
Publication Year :
2024

Abstract

Background: Despite recent guideline recommendations, quantitative perfusion (QP) estimates of myocardial blood flow from cardiac magnetic resonance (CMR) have only been sparsely validated. Furthermore, the additional diagnostic value of utilizing QP in addition to the traditional visual expert interpretation of stress-perfusion CMR remains unknown. The aim was to investigate the correlation between myocardial blood flow measurements estimated by CMR, positron emission tomography, and invasive coronary thermodilution. The second aim is to investigate the diagnostic performance of CMR-QP to identify obstructive coronary artery disease (CAD).<br />Methods: Prospectively enrolled symptomatic patients with >50% diameter stenosis on computed tomography angiography underwent dual-bolus CMR and positron emission tomography with rest and adenosine-stress myocardial blood flow measurements. Subsequently, an invasive coronary angiography (ICA) with fractional flow reserve and thermodilution-based coronary flow reserve was performed. Obstructive CAD was defined as both anatomically severe (>70% diameter stenosis on quantitative coronary angiography) or hemodynamically obstructive (ICA with fractional flow reserve ≤0.80).<br />Results: About 359 patients completed all investigations. Myocardial blood flow and reserve measurements correlated weakly between estimates from CMR-QP, positron emission tomography, and ICA-coronary flow reserve (r<0.40 for all comparisons). In the diagnosis of anatomically severe CAD, the interpretation of CMR-QP by an expert reader improved the sensitivity in comparison to visual analysis alone (82% versus 88% [ P =0.03]) without compromising specificity (77% versus 74% [ P =0.28]). In the diagnosis of hemodynamically obstructive CAD, the accuracy was only moderate for a visual expert read and remained unchanged when additional CMR-QP measurements were interpreted.<br />Conclusions: CMR-QP correlates weakly to myocardial blood flow measurements by other modalities but improves diagnosis of anatomically severe CAD.<br />Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03481712.<br />Competing Interests: Disclosures Dr Rasmussen acknowledges support in terms of a research grant (PD5Y-2023001-DCA) from the Danish Cardiovascular Academy, which is funded by the Novo Nordisk Foundation, grant NNF20SA0067242, and The Danish Heart Foundation. Dr Winther acknowledges support from the Novo Nordisk Foundation Clinical Emerging Investigator grant (NNF21OC0066981). Dr Bøttcher is a previous employee and a shareholder of Circle Cardiovascular Imaging, Inc. S.E. Petersen provides consultancy to and was a previous stockowner of Circle Cardiovascular Imaging, Inc. Dr Bøttcher discloses advisory board participation for NOVO Nordisk, AstraZeneca, Pfizer, Boehringer Ingelheim, Bayer, Sanofi, Novartis, AMGEN, CLS-Behring, and Acarix. The other authors report no conflicts.

Details

Language :
English
ISSN :
1942-0080
Volume :
17
Issue :
6
Database :
MEDLINE
Journal :
Circulation. Cardiovascular imaging
Publication Type :
Academic Journal
Accession number :
38889213
Full Text :
https://doi.org/10.1161/CIRCIMAGING.124.016635