Back to Search
Start Over
A Conservative Technique for Fractured Implant Abutment Screw Retrieval on an Internal Connection Implant: Proof of Concept.
- Source :
-
The Journal of oral implantology [J Oral Implantol] 2024 Oct 01; Vol. 50 (5), pp. 519-523. - Publication Year :
- 2024
-
Abstract
- Broken screw removal from the implant connection is a common but challenging process. Several proposed methods and technical solutions may result in unsuccessful removal; thus, a novel, more conservative, risk-free method is proposed as a first attempt. The proposal is to use a silicon restoration holder to be twisted counterclockwise on the dried surface of the broken fragment inside the implant connection. This method, within the limitations of a minimal case series, yielded 100% results; however, despite previous attempts with less conservative techniques, this approach showed no efficacy. This article aims to promote the use of silicon restoration holders as a minimally invasive first attempt at broken screw retrieval treatment before considering other options.
Details
- Language :
- English
- ISSN :
- 1548-1336
- Volume :
- 50
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- The Journal of oral implantology
- Publication Type :
- Academic Journal
- Accession number :
- 38867372
- Full Text :
- https://doi.org/10.1563/aaid-joi-D-24-00064