Back to Search Start Over

A Conservative Technique for Fractured Implant Abutment Screw Retrieval on an Internal Connection Implant: Proof of Concept.

Authors :
Farronato D
Romano L
Dani G
Messina G
Miceli B
Azzi L
Source :
The Journal of oral implantology [J Oral Implantol] 2024 Oct 01; Vol. 50 (5), pp. 519-523.
Publication Year :
2024

Abstract

Broken screw removal from the implant connection is a common but challenging process. Several proposed methods and technical solutions may result in unsuccessful removal; thus, a novel, more conservative, risk-free method is proposed as a first attempt. The proposal is to use a silicon restoration holder to be twisted counterclockwise on the dried surface of the broken fragment inside the implant connection. This method, within the limitations of a minimal case series, yielded 100% results; however, despite previous attempts with less conservative techniques, this approach showed no efficacy. This article aims to promote the use of silicon restoration holders as a minimally invasive first attempt at broken screw retrieval treatment before considering other options.

Details

Language :
English
ISSN :
1548-1336
Volume :
50
Issue :
5
Database :
MEDLINE
Journal :
The Journal of oral implantology
Publication Type :
Academic Journal
Accession number :
38867372
Full Text :
https://doi.org/10.1563/aaid-joi-D-24-00064