Back to Search Start Over

Adsorption efficiency of chitosan/clinoptilolite (CS/CZ) composite for effective removal of Cd +2 and Cr +6 ions from wastewater effluents of dairy cattle farms.

Authors :
Mohammed AN
Source :
Environmental monitoring and assessment [Environ Monit Assess] 2024 Jun 12; Vol. 196 (7), pp. 611. Date of Electronic Publication: 2024 Jun 12.
Publication Year :
2024

Abstract

The wastewater effluent is responsible for the major ecological impact of the dairy sectors. To avoid the negative consequences of heavy metal pollution on the ecosystem, creative, affordable, and efficient treatment methods are now required before the effluent flows into the surrounding area. This study was aimed at assessing the effectiveness of three different adsorbents for Cd <superscript>+2</superscript> and Cr <superscript>+6</superscript> ions from wastewater effluents of dairy farms, including chitosan (CS), clinoptilolite zeolite (CZ), and chitosan/clinoptilolite zeolite (CS/CZ) composite. The adsorption kinetics of the CS/CZ composite were established using the effects of the key variables (pH, agitation speed, adsorbent concentrations, and contact durations). The removal (%) and adsorption capacities, q <subscript>e</subscript> (mg/g), were calculated using the data from the adsorption kinetics. Wastewater samples (nā€‰=ā€‰60) were collected from the wastewater effluents of five farms. Cd <superscript>+2</superscript> and Cr <superscript>+6</superscript> ion concentrations in all collected samples were determined. Following the CS/CZ composite creation, it was characterized using scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction (X-RD), and Fourier-transform infrared spectrum (FT-IR). The CS/CZ composite had an adsorption capacity of 92.4 and 96.5 mg/g for both Cd <superscript>+2</superscript> and Cr <superscript>+6</superscript> ions at a concentration of 2.0 g/100 ml, respectively, while the CZ adsorption capacities for the two ions were 87.5 mg/g and 61.0 mg/g, respectively, at 4.0 g/100 ml concentration. The CS was achieved at 55.56 mg/g and 33.3 mg/g, respectively, at the same concentration. The efficiency of heavy metal removal was enhanced by increasing adsorbent concentration, agitation speed, and contact duration. Using CS/CZ composite at 2.0 g/100 ml concentration, 180 min of contact time, and 300 rpm agitation speed, the greatest removal efficiencies for Cd <superscript>+2</superscript> and Cr <superscript>+6</superscript> ions (96.43 and 98.75%, respectively) were demonstrated.<br /> (© 2024. The Author(s), under exclusive licence to Springer Nature Switzerland AG.)

Details

Language :
English
ISSN :
1573-2959
Volume :
196
Issue :
7
Database :
MEDLINE
Journal :
Environmental monitoring and assessment
Publication Type :
Academic Journal
Accession number :
38862850
Full Text :
https://doi.org/10.1007/s10661-024-12749-1