Method to quickly estimate T 1 value by suppressing spin exchange relaxation and magnetic field gradient relaxation in atomic sensors.

Authors :
Wang X
Li J
Qu C
Cheng Y
Zhang J
Source :
Optics express [Opt Express] 2024 Apr 22; Vol. 32 (9), pp. 15380-15389.
Publication Year :
2024

Abstract

The accuracy of atomic sensor is determined by the transverse nuclear spin relaxation time (T <subscript>2</subscript> ). As the longitudinal nuclear spin relaxation time (T <subscript>1</subscript> ) is the upper limit of T <subscript>2</subscript> , it becomes an important metric for evaluating the merits of alkali vapor cells. However, the conventional method for measuring T <subscript>1</subscript> of pulse delay takes dozens of minutes, which will increase the effect of random errors during the testing process. In order to solve this problem, a method to quickly estimate the value of T <subscript>1</subscript> is proposed by suppressing the influence of spin exchange relaxation and magnetic field gradient relaxation terms on T <subscript>2</subscript> . Experimental results indicate that the accuracy is maintained at above 95%, and the testing time is reduced to less than 5%.

Details

Language :
English
ISSN :
1094-4087
Volume :
32
Issue :
9
Database :
MEDLINE
Journal :
Optics express
Publication Type :
Academic Journal
Accession number :
38859190
Full Text :
https://doi.org/10.1364/OE.522737