Back to Search Start Over

A novel method to perform morphological measurements on three-dimensional (3D) models of the calcaneus based on computed tomography (CT)-imaging.

Authors :
Wakker AM
Van Lieshout EMM
De Boer AS
Cornelissen BMW
Verhofstad MHJ
Van Walsum T
Visser JJ
Van Vledder MG
Source :
Quantitative imaging in medicine and surgery [Quant Imaging Med Surg] 2024 Jun 01; Vol. 14 (6), pp. 3778-3788. Date of Electronic Publication: 2024 Apr 17.
Publication Year :
2024

Abstract

Background: While current preoperative and postoperative assessment of the fractured and surgically reconstructed calcaneus relies on computed tomography (CT)-imaging, there are no established methods to quantify calcaneus morphology on CT-images. This study aims to develop a semi-automated method for morphological measurements of the calcaneus on three-dimensional (3D) models derived from CT-imaging.<br />Methods: Using CT data, 3D models were created from healthy, fractured, and surgically reconstructed calcanei. Böhler's angle (BA) and Critical angle of Gissane (CAG) were measured on conventional lateral radiographs and corresponding 3D CT reconstructions using a novel point-based method with semi-automatic landmark placement by three observers. Intraobserver and interobserver reliability scores were calculated using intra-class correlation coefficient (ICC). In addition, consensus among observers was calculated for a maximal allowable discrepancy of 5 and 10 degrees for both methods.<br />Results: Imaging data from 119 feet were obtained (40 healthy, 39 fractured, 40 reconstructed). Semi-automated measurements on 3D models of BA and CAG showed excellent reliability (ICC: 0.87-1.00). The manual measurements on conventional radiographs had a poor-to-excellent reliability (ICC: 0.22-0.96). In addition, the percentage of consensus among observers was much higher for the 3D method when compared to conventional two-dimensional (2D) measurements.<br />Conclusions: The proposed method enables reliable and reproducible quantification of calcaneus morphology in 3D models of healthy, fractured and reconstructed calcanei.<br />Competing Interests: Conflicts of Interest: All authors have completed the ICMJE uniform disclosure form (available at https://qims.amegroups.com/article/view/10.21037/qims-24-142/coif). A.M.W. reports that he received funding from Ostheosynthesis & Trauma Care Foundation for research about the calcaneus. The other authors have no conflicts of interest to declare.<br /> (2024 Quantitative Imaging in Medicine and Surgery. All rights reserved.)

Details

Language :
English
ISSN :
2223-4292
Volume :
14
Issue :
6
Database :
MEDLINE
Journal :
Quantitative imaging in medicine and surgery
Publication Type :
Academic Journal
Accession number :
38846290
Full Text :
https://doi.org/10.21037/qims-24-142