Back to Search Start Over

Investigating the association between self-reported physical function, temporo-spatial parameters, walking kinematics and community-based ambulatory activity: Analysis of post-operative hip preservation patients.

Authors :
Stevens WR
Anable NR
Barrett C
Jeans KA
Podeszwa DA
Source :
Gait & posture [Gait Posture] 2024 Sep; Vol. 113, pp. 53-57. Date of Electronic Publication: 2024 May 28.
Publication Year :
2024

Abstract

Introduction: Wearable sensors provide the ability to assess ambulatory activity in the community after hip preservation surgery (HPS). In combination with gait analysis and patient reported outcomes, more perspective on post-operative function is gained. The purpose of this study was to assess the relationship between self-reported function/activity, temporo-spatial parameters and walking kinematics to objectively measured ambulatory activity.<br />Methods: Forty-nine participants (38 Females; age range 16-38 years) who were five years or more post-surgery and the following diagnoses were included: Acetabular Dysplasia (n=34), Femoroacetabular Impingement (n=12) and Legg-Calvé Perthes disease (n=3). Participants underwent 3D gait analysis and gait deviations were quantified using the Gait Deviation Index (GDI) and Gait Profile Score (GPS). Temporo-spatial parameters were also calculated. Self-reported pain/function and activity level were assessed via the Harris Hip Score (HHS) and UCLA Activity Scale (UCLA). Participants wore a StepWatch Activity Monitor in their community and the Intensity/Duration of ambulatory bouts were analyzed. Spearman correlation coefficients were run to assess the following relationships: in-lab walking measures, self-reported function/activity vs.community ambulatory activity.<br />Results: There were no statistically significant correlations between HHS, UCLA or temporospatial parameters with ambulatory activity (p>0.05). Worsening gait deviations (GDI/GPS scores) correlated with daily total ambulatory time (ρ=0.284/-0.284, p<0.05), time spent in Short duration ambulatory bouts (ρ=-0.321/0.321, p<0.05) and the amount of time in Long duration ambulatory bouts (ρ=0.366/-0.366, p<0.05). The amount of time spent in Easy intensity/Short duration and Easy intensity/Long duration ambulatory bouts did have a weak correlation with the GDI and GPS (p<0.05).<br />Conclusions: In HPS patients after long-term follow up, ambulatory activity in the community did not correlate with patient reported outcomes but there was a weak correlation with the presence of gait deviations. Incorporating wearable sensors to assess community ambulatory bout intensity/duration, provides additional quantifiable measures into the overall function of patients following HPS.<br />Competing Interests: Declaration of Competing Interest All authors have no relevant conflicts of interests to disclose.<br /> (Copyright © 2024 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1879-2219
Volume :
113
Database :
MEDLINE
Journal :
Gait & posture
Publication Type :
Academic Journal
Accession number :
38843707
Full Text :
https://doi.org/10.1016/j.gaitpost.2024.05.027