An optimised and validated surrogate analyte A-TEEM-PARAFAC-PLS technique for detecting and quantifying the biological oxygen demand in surface water.
- Source :
-
Analytical sciences : the international journal of the Japan Society for Analytical Chemistry [Anal Sci] 2024 Sep; Vol. 40 (9), pp. 1683-1694. Date of Electronic Publication: 2024 Jun 01. - Publication Year :
- 2024
-
Abstract
- A 5-day test duration makes BOD <subscript>5</subscript> measurement unsatisfactory and hinders the development of a quick technique. Protein-like fluorescence peaks show a strong correlation between the BOD characteristics and the fluorescence intensities. For identifying and measuring BOD in surface water, a simultaneous absorbance-transmittance and fluorescence excitation-emission matrices (A-TEEM) method combined with PARAFAC (parallel factor) and PLS (partial least squares) analyses was developed using a tyrosine and tryptophan (tyr-trpt) mix as a surrogate analyte for BOD. The use of a surrogate analyte was decided upon due to lack of fluorescent BOD standards. Tyr-trpt mix standard solutions were added to surface water samples to prepare calibration and validation samples. PARAFAC analysis of excitation-emission matrices detected the tyr-trpt mix in surface water. PLS modelling demonstrated significant linearity (R <superscript>2</superscript> = 0.991) between the predicted and measured tyr-trypt mix concentrations, and accuracy and robustness were all acceptable per the ICH Q2 (R2) and ASTM multivariate calibration/validation procedures guidelines. Based on a suitable and workable surrogate analyte method, these results imply that BOD can be detected and quantified using the A-TEEM-PARAFAC-PLS method. Very positive comparability between tyr-trypt mix concentrations was found, suggesting that tyr-trypt mix might eventually take the place of a BOD-based sampling protocol. Overall, this approach offers a novel tool that can be quickly applied in water treatment plant settings and is a step in supporting the trend toward rapid BOD determination in waters. Further studies should demonstrate the wide application of the method using real wastewater samples from various water treatment facilities.<br /> (© 2024. The Author(s), under exclusive licence to The Japan Society for Analytical Chemistry.)
Details
- Language :
- English
- ISSN :
- 1348-2246
- Volume :
- 40
- Issue :
- 9
- Database :
- MEDLINE
- Journal :
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
- Publication Type :
- Academic Journal
- Accession number :
- 38822950
- Full Text :
- https://doi.org/10.1007/s44211-024-00605-8