Back to Search
Start Over
Electrochemical detection of myoglobin using an ultrasensitive label-free sensor derived from cubic-ZIF67@Au-rGOF-NH 2 composite of MOF and GOF.
- Source :
-
Analytical biochemistry [Anal Biochem] 2024 Sep; Vol. 692, pp. 115571. Date of Electronic Publication: 2024 May 23. - Publication Year :
- 2024
-
Abstract
- Markers of myocardial injury, such as myoglobin (Mb), are substances swiftly released into the peripheral bloodstream upon myocardial cell injury or altered cardiac activity. During the onset of acute myocardial infarction, patients experience a significant surge in serum Mb levels. Given this, precise detection of Mb is essential, necessitating the development of innovative assays to optimize detection capabilities. This study introduces the synthesis of a three-dimensional hierarchical nanocomposite, Cubic-ZIF67@Au-rGOF-NH <subscript>2</subscript> , utilizing aminated reduced graphene oxide and zeolite imidazolium ester framework-67 (ZIF67) as foundational structures. Notably, this novel material, applied in a label-free electrochemical immunosensor, presents a groundbreaking approach for detecting myocardial injury markers. Experimental outcomes revealed ZIF67 and AuNPs exhibit enhanced affinity and growth on the 3D-rGOF-NH <subscript>2</subscript> matrix, thus amplifying electrical conductivity while preserving the inherent electrochemical attributes of ZIF67. As a result, the Cubic-ZIF67@Au-rGOF-NH <subscript>2</subscript> label-free electrochemical immunosensor exhibited a broad detection range and high sensitivity for Mb. The derived standard curve was ΔIp = 16.67552lgC+275.245 (R = 0.993) with a detection threshold of 3.47 fg/ml. Moreover, recoveries of standards spiked into samples ranged between 96.3% and 108.7%. Importantly, the devised immunosensor retained notable selectivity against non-target proteins, proving its potential clinical utility based on exemplary sample analysis performance.<br />Competing Interests: Declaration of competing interest Dear Editors, I am authorized on behalf of all the authors of this article to confirm that no author has any conflict of interest to disclose, all authors have approved the version submitted for publication, the work in this article is original and has not been published previously, and the article is not under consideration by any other journal. We thank you for your kind consideration of our article. Please do not hesitate to contact me directly if any further information is required. I look forward to hearing from you.<br /> (Copyright © 2024. Published by Elsevier Inc.)
Details
- Language :
- English
- ISSN :
- 1096-0309
- Volume :
- 692
- Database :
- MEDLINE
- Journal :
- Analytical biochemistry
- Publication Type :
- Academic Journal
- Accession number :
- 38796119
- Full Text :
- https://doi.org/10.1016/j.ab.2024.115571