Back to Search Start Over

The reliability of a Biometrics device as a tool for assessing hand grip and pinch strength, in a Polish cohort-A prospective observational study.

Authors :
Leszczak J
Pniak B
Drużbicki M
Guzik A
Source :
PloS one [PLoS One] 2024 May 23; Vol. 19 (5), pp. e0303648. Date of Electronic Publication: 2024 May 23 (Print Publication: 2024).
Publication Year :
2024

Abstract

The aim of the study was to assess the external and internal compatibility of the Biometrics E-LINK EP9 evaluation system device in the area of hand grip and pinch strength in the Polish population. The testing of hand grip and pinch strength was carried out among 122 healthy students. Two examiners performed hand grip and pinch strength measurements with a Biometrics E-LINK EP9 evaluation system device. Measurements were made for the right and left hands. The same people were tested again two weeks later, under the same conditions. The scores of one rater on the first and second tests were compared for reproducibility, and the scores of the two raters were compared to assess the reliability of the instrument. The measurements were found to be highly consistent both between the investigators and between the tests in the hand grip dynamometer test. The findings show high values of the Pearson's correlation coefficient equal or close to 1, as well as the interclass correlation coefficient (ICC) >0.9. Analysis of pinch strength measurements performed using the pinchmeter also found high values of the Pearson's correlation coefficient close to 1, as well as the interclass correlation coefficient >0.9; this reflects high agreement between the measurements performed by two investigators as well as assessments performed by one investigator at time intervals. These findings were confirmed by analyses performed using Bland-Altman plots. The measurements made with the Biometrics E-link EP9 evaluation system show high internal and external consistency in hand grip and pinch strength assessment. Biometrics E-link EP9 can be recommended for daily clinical practice.<br />Competing Interests: The authors have declared that no competing interests exist.<br /> (Copyright: © 2024 Leszczak et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.)

Details

Language :
English
ISSN :
1932-6203
Volume :
19
Issue :
5
Database :
MEDLINE
Journal :
PloS one
Publication Type :
Academic Journal
Accession number :
38781271
Full Text :
https://doi.org/10.1371/journal.pone.0303648