Back to Search
Start Over
Catheter-based pulmonary vein isolation fails to prevent transient atrial arrhythmogenic changes related to acute obstructive respiratory events in a porcine model.
- Source :
-
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology [Europace] 2024 Jun 03; Vol. 26 (6). - Publication Year :
- 2024
-
Abstract
- Aims: Pulmonary vein isolation (PVI) is the corner stone of modern rhythm control strategies in patients with atrial fibrillation (AF). Sleep-disordered breathing (SDB) is prevalent in more than 50% of patients undergoing AF ablation, and studies have indicated a greater recurrence rate after PVI in patients with SDB. Herein, we study the effect of catheter-based PVI on AF in a pig model for SDB.<br />Methods and Results: In 11 sedated spontaneously breathing pigs, obstructive apnoeas were simulated by 75 s of intermittent negative upper airway pressure (INAP) applied by a negative pressure device connected to the endotracheal tube. Intermittent negative upper airway pressures were performed before and after PVI. AF-inducibility and atrial effective refractory periods (aERPs) were determined before and during INAP by programmed atrial stimulation. Pulmonary vein isolation prolonged the aERP by 48 ± 27 ms in the right atrium (RA) (P < 0.0001) and by 40 ± 34 ms in the left atrium (LA) (P = 0.0004). Following PVI, AF-inducibility dropped from 28 ± 26% to 0% (P = 0.0009). Intermittent negative upper airway pressure was associated with a transient aERP-shortening (ΔaERP) in both atria, which was not prevented by PVI (INAP indued ΔaERP after PVI in the RA: -57 ± 34 ms, P = 0.0002; in the LA: -42 ± 24 ms, P < 0.0001). Intermittent negative upper airway pressure was associated with a transient increase in AF-inducibility (from 28 ± 26% to 69 ± 21%; P = 0.0008), which was not attenuated by PVI [INAP-associated AF-inducibility after PVI: 58 ± 33% (P = 0.5)].<br />Conclusion: Transient atrial arrhythmogenic changes related to acute obstructive respiratory events are not prevented by electrical isolation of the pulmonary veins, which partially explains the increased AF recurrence in patients with SDB after PVI procedures.<br />Competing Interests: Conflict of interest: none declared.<br /> (© The Author(s) 2024. Published by Oxford University Press on behalf of the European Society of Cardiology.)
- Subjects :
- Animals
Swine
Sleep Apnea, Obstructive physiopathology
Treatment Failure
Heart Rate
Heart Atria physiopathology
Heart Atria surgery
Pulmonary Veins surgery
Pulmonary Veins physiopathology
Atrial Fibrillation physiopathology
Atrial Fibrillation surgery
Atrial Fibrillation prevention & control
Atrial Fibrillation diagnosis
Disease Models, Animal
Catheter Ablation methods
Subjects
Details
- Language :
- English
- ISSN :
- 1532-2092
- Volume :
- 26
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
- Publication Type :
- Academic Journal
- Accession number :
- 38758963
- Full Text :
- https://doi.org/10.1093/europace/euae132