Back to Search
Start Over
Determination of vancomycin and meropenem in serum and synovial fluid of patients with prosthetic joint infections using UPLC-MS/MS.
- Source :
-
Journal of mass spectrometry : JMS [J Mass Spectrom] 2024 Jun; Vol. 59 (6), pp. e5041. - Publication Year :
- 2024
-
Abstract
- Numerous studies have suggested that intra-articular administration of antibiotics following primary revision surgery may be one of the methods for treating prosthetic joint infection (PJI). Vancomycin and meropenem are the two most commonly used antibiotics for local application. Determining the concentrations of vancomycin and meropenem in the serum and synovial fluid of patients with PJI plays a significant role in further optimizing local medication schemes and effectively eradicating biofilm infections. This study aimed to establish a rapid, sensitive, and accurate ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for determining the concentrations of vancomycin and meropenem in human serum and synovial fluid. Serum samples were processed using acetonitrile precipitation of proteins and dichloromethane extraction, while synovial fluid samples were diluted before analysis. Chromatographic separation was achieved in 6 min on a Waters Acquity UPLC BEH C18 column, with the mobile phase consisting of 0.1% formic acid in water (solvent A) and acetonitrile (solvent B). Quantification was carried out using a Waters XEVO TQD triple quadrupole mass spectrometer with an electrospray ionization (ESI) source in positive ion mode. The multiple reaction monitoring (MRM) mode was employed to detect the following quantifier ion transitions: 717.95-99.97 (norvancomycin), 725.90-100.04 (vancomycin), 384.16-67.99 (meropenem). The method validation conformed to the guidelines of the FDA and the Chinese Pharmacopoeia. The method demonstrated good linearity within the range of 0.5-50 μg/ml for serum and 0.5-100 μg/ml for synovial fluid. Selectivity, intra-day and inter-day precision and accuracy, extraction recovery, matrix effect, and stability validation results all met the required standards. This method has been successfully applied in the pharmacokinetic/pharmacodynamic (PK/PD) studies of patients with PJI.<br /> (© 2024 John Wiley & Sons Ltd.)
- Subjects :
- Humans
Chromatography, High Pressure Liquid methods
Reproducibility of Results
Male
Limit of Detection
Middle Aged
Liquid Chromatography-Mass Spectrometry
Tandem Mass Spectrometry methods
Vancomycin blood
Vancomycin analysis
Vancomycin pharmacokinetics
Synovial Fluid chemistry
Meropenem analysis
Meropenem blood
Meropenem pharmacokinetics
Prosthesis-Related Infections drug therapy
Prosthesis-Related Infections blood
Anti-Bacterial Agents blood
Anti-Bacterial Agents analysis
Anti-Bacterial Agents pharmacokinetics
Anti-Bacterial Agents therapeutic use
Subjects
Details
- Language :
- English
- ISSN :
- 1096-9888
- Volume :
- 59
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- Journal of mass spectrometry : JMS
- Publication Type :
- Academic Journal
- Accession number :
- 38751321
- Full Text :
- https://doi.org/10.1002/jms.5041