Automatic left ventricle volume and mass quantification from 2D cine-MRI: Investigating papillary muscle influence.

Authors :
Baccouch W
Oueslati S
Solaiman B
Lahidheb D
Labidi S
Source :
Medical engineering & physics [Med Eng Phys] 2024 May; Vol. 127, pp. 104162. Date of Electronic Publication: 2024 Mar 29.
Publication Year :
2024

Abstract

Objective: Early detection of cardiovascular diseases is based on accurate quantification of the left ventricle (LV) function parameters. In this paper, we propose a fully automatic framework for LV volume and mass quantification from 2D-cine MR images already segmented using U-Net.<br />Methods: The general framework consists of three main steps: Data preparation including automatic LV localization using a convolution neural network (CNN) and application of morphological operations to exclude papillary muscles from the LV cavity. The second step consists in automatically extracting the LV contours using U-Net architecture. Finally, by integrating temporal information which is manifested by a spatial motion of myocytes as a third dimension, we calculated LV volume, LV ejection fraction (LVEF) and left ventricle mass (LVM). Based on these parameters, we detected and quantified cardiac contraction abnormalities using Python software.<br />Results: CNN was trained with 35 patients and tested on 15 patients from the ACDC database with an accuracy of 99,15 %. U-Net architecture was trained using ACDC database and evaluated using local dataset with a Dice similarity coefficient (DSC) of 99,78 % and a Hausdorff Distance (HD) of 4.468 mm (p < 0,001). Quantification results showed a strong correlation with physiological measures with a Pearson correlation coefficient (PCC) of 0,991 for LV volume, 0.962 for LVEF, 0.98 for stroke volume (SV) and 0.923 for LVM after pillars' elimination. Clinically, our method allows regional and accurate identification of pathological myocardial segments and can serve as a diagnostic aid tool of cardiac contraction abnormalities.<br />Conclusion: Experimental results prove the usefulness of the proposed method for LV volume and function quantification and verify its potential clinical applicability.<br />Competing Interests: Declaration of competing interest The authors declare that they have no conflict of interest.<br /> (Copyright © 2024 IPEM. Published by Elsevier Ltd. All rights reserved.)

Details

Language :
English
ISSN :
1873-4030
Volume :
127
Database :
MEDLINE
Journal :
Medical engineering & physics
Publication Type :
Academic Journal
Accession number :
38692762
Full Text :
https://doi.org/10.1016/j.medengphy.2024.104162