Bioprosthetic mitral valve thrombosis: the role of cardiac CT in diagnosis and guiding the management.
- Source :
-
BMJ case reports [BMJ Case Rep] 2024 Apr 29; Vol. 17 (4). Date of Electronic Publication: 2024 Apr 29. - Publication Year :
- 2024
-
Abstract
- A patient in his 60s with a bioprosthetic aortic and mitral valve replacement presented with dyspnoea, tiredness and dizziness 2 years postoperatively. Transthoracic echocardiography showed mitral valve stenosis and increased pulmonary artery pressure suggesting bioprosthetic valve failure. Cardiac CT confirmed the diagnosis of bioprosthetic mitral valve thrombosis. Treatment with anticoagulation resulted in a remarkable improvement of the valve area and gradient and complete resolution of the thrombus. Herein, we report a case of rare bioprosthetic mitral valve thrombosis.<br />Competing Interests: Competing interests: None declared.<br /> (© BMJ Publishing Group Limited 2024. No commercial re-use. See rights and permissions. Published by BMJ.)
- Subjects :
- Humans
Male
Mitral Valve Stenosis surgery
Mitral Valve Stenosis diagnostic imaging
Anticoagulants therapeutic use
Echocardiography
Heart Valve Prosthesis Implantation adverse effects
Middle Aged
Prosthesis Failure
Bioprosthesis adverse effects
Thrombosis diagnostic imaging
Thrombosis etiology
Thrombosis drug therapy
Heart Valve Prosthesis adverse effects
Mitral Valve diagnostic imaging
Mitral Valve surgery
Tomography, X-Ray Computed
Subjects
Details
- Language :
- English
- ISSN :
- 1757-790X
- Volume :
- 17
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- BMJ case reports
- Publication Type :
- Academic Journal
- Accession number :
- 38684360
- Full Text :
- https://doi.org/10.1136/bcr-2023-258127