Back to Search
Start Over
Development of an Eye Irritation Test Method Using an In-House Fabrication of a Reconstructed Human Cornea-like Epithelium Model for Eye Hazard Identification.
- Source :
-
Bioengineering (Basel, Switzerland) [Bioengineering (Basel)] 2024 Mar 22; Vol. 11 (4). Date of Electronic Publication: 2024 Mar 22. - Publication Year :
- 2024
-
Abstract
- In a previous study, a novel human corneal-like epithelium model utilizing an immortalized human corneal epithelial cell line (iHCE-NY1) was developed as an alternative to animal models to identify chemicals not classified under the United Nations Globally Harmonized System of Classification and Labeling of Chemicals (GHS) and was evaluated following the criteria of Test Guideline 492 of the Organization for Economic Co-operation and Development (OECD). In the present study, our aim was to establish an eye irritation test protocol using the iHCE-NY1 model to classify liquid chemicals under the GHS ocular hazard categories: no effect, no classification (No Cat.), Category 2 (Cat. 2) reversible effects, and Category 1 (Cat. 1) irreversible eye damage. The protocol involved exposing the iHCE-NY1 model to 31 liquid test chemicals for 5 min, followed by observation at post-incubation periods (PIPs) to assess recovery. Classification was based on cell viability, and histopathological findings on PIP days 7, 14, and 21. The outcomes were compared with an established database of classifications. All Cat. 1 liquid chemicals, 62.5% of No Cat., and 63.2% of Cat. 2 were correctly categorized. This study demonstrates that the iHCE-NY1 model can not only distinguish No Cat. test liquid chemicals but also differentiate between Cat. 2 and Cat. 1 liquid chemicals.
Details
- Language :
- English
- ISSN :
- 2306-5354
- Volume :
- 11
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- Bioengineering (Basel, Switzerland)
- Publication Type :
- Academic Journal
- Accession number :
- 38671724
- Full Text :
- https://doi.org/10.3390/bioengineering11040302