Back to Search
Start Over
Geometric Analysis of the Gore Excluder Conformable Endoprosthesis in the Infrarenal Aortic Neck: One Year Results of the EXCeL Registry.
- Source :
-
European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery [Eur J Vasc Endovasc Surg] 2024 Dec; Vol. 68 (6), pp. 720-727. Date of Electronic Publication: 2024 Apr 24. - Publication Year :
- 2024
-
Abstract
- Objective: The Gore Excluder Conformable Endoprosthesis (CEXC) is designed to treat challenging infrarenal anatomy because of its active angulation control, repositionability, and enhanced conformability. This study evaluated 30 day and one year position and apposition of the CEXC in the infrarenal neck.<br />Methods: Patients treated with the CEXC between 2018 and 2022 with an available 30 day computed tomography angiogram (CTA) were selected from four hospitals in a prospective registry. Endograft apposition (shortest apposition length [SAL]) and position (shortest fabric distance [SFD]) were assessed on the 30 day and one year CTAs. Maximum infrarenal aortic curvature was compared between the pre- and post-operative CTAs to evaluate conformability of the CEXC.<br />Results: There were 87 patients with a 30 day CTA, and for 56 of these patients the one year CTA was available. Median (interquartile range [IQR]) pre-operative neck length was 22 mm (IQR 15, 32) and infrarenal angulation was 52° (IQR 31, 72). Median SAL was 21.2 mm (IQR 14.0, 29.3) at 30 days for all included patients. The SAL in 13 patients (15%) was < 10 mm at 30 days, and one patient had a SAL of 0 mm and a type Ia endoleak. There was no significant difference in SAL between patients within and outside instructions for use. The SAL significantly increased by 1.1 mm (IQR -2.3, 4.7; p = .042) at one year. The SAL decreased in seven patients (13%), increased in 13 patients (23%), and remained stable in 36 patients (64%). Median SFD was 2.0 mm (IQR 0.5, 3.6) at 30 days, which slightly increased by 0.3 mm (IQR -0.5, 1.8; p = .019) at one year. One patient showed migration (SFD increase ≥ 5 mm). Median endograft tilt was 15.8° (IQR 9.7, 21.4). Pre-operative maximum infrarenal curvature was 36 m <superscript>-1</superscript> (IQR 26, 56) and did not significantly change thereafter.<br />Conclusion: In most patients, the CEXC was implanted close to the renal arteries, and sufficient (≥ 10 mm) post-operative apposition was achieved at 30 days, which slightly increased at one year. Post-operative endograft tilt was relatively low, and aortic geometry remained unchanged after implantation of the CEXC, probably due to its high conformability.<br /> (Copyright © 2024 The Authors. Published by Elsevier B.V. All rights reserved.)
- Subjects :
- Humans
Male
Female
Aged
Prospective Studies
Treatment Outcome
Stents
Aorta, Abdominal surgery
Aorta, Abdominal diagnostic imaging
Aged, 80 and over
Time Factors
Blood Vessel Prosthesis
Registries
Prosthesis Design
Aortic Aneurysm, Abdominal surgery
Aortic Aneurysm, Abdominal diagnostic imaging
Blood Vessel Prosthesis Implantation instrumentation
Blood Vessel Prosthesis Implantation adverse effects
Endovascular Procedures instrumentation
Endovascular Procedures adverse effects
Computed Tomography Angiography
Subjects
Details
- Language :
- English
- ISSN :
- 1532-2165
- Volume :
- 68
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery
- Publication Type :
- Academic Journal
- Accession number :
- 38670221
- Full Text :
- https://doi.org/10.1016/j.ejvs.2024.04.026