Back to Search
Start Over
Analysis of the effectiveness of the latest 4th-generation cryoballoon catheters in pulmonary vein isolation using high-resolution mapping.
- Source :
-
Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese [Hellenic J Cardiol] 2024 Apr 23. Date of Electronic Publication: 2024 Apr 23. - Publication Year :
- 2024
- Publisher :
- Ahead of Print
-
Abstract
- Background: Long-term data showed that up to 27% of pulmonary veins are reconnected using cryoballoon ablation. This study aimed to evaluate the efficacy of the latest 4th-generation cryoballoon catheters using ultra high-resolution mapping.<br />Methods: In patients with atrial fibrillation, a standard pulmonary vein isolation (PVI) with the latest 4th-generation cryoballoon catheter (Arctic Front Advance PRO, Medtronic Minneapolis, USA) and the spiral mapping catheter (Achieve Advance, Medtronic, Minneapolis, MN, USA) was performed. Subsequently, high-resolution mapping was achieved using the novel multipolar grid mapping catheter (Advisor HD Grid SE, Abbott Laboratories, USA). Follow-up was obtained after 6 months by means of a 7-day Holter electrocardiogram.<br />Results: In our study, acute PVI was successfully achieved in all 31 patients. The latest 4th-generation cryoballoon catheter is safe in the acute phase of PVI. Additional high-resolution mapping (mean points per map 21,001 ± 4911) using the multipolar grid mapping catheter enabled us to identify residual gaps only in the carina pulmonary vein region; therefore, no additional ablation was performed. Three of 31 patients (10%) presented with atrial arrhythmia recurrence always related with pulmonary vein reconnection; using high-resolution mapping had no additional benefit in identifying pulmonary veins in which reconnection will occur.<br />Conclusion: The utility of additional high-density mapping, facilitated by the HD Grid catheter after PVI with the 4th-generation cryoballoon catheter do not substantiate a discernible advantage over conventional mapping methodologies, particularly, the spiral mapping catheter. Residual carinal conduction was observed in a substantial cohort of patients (48%), highlighting a persistent challenge in achieving complete electrical isolation.<br />Competing Interests: Conflict of interest disclosure MG was a speaker for Abbott, Bristol-Myers Squibb, Novartis, Pfizer, and an advisor for Boehringer Ingelheim.<br /> (Copyright © 2024 Hellenic Society of Cardiology. Published by Elsevier Inc. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 2241-5955
- Database :
- MEDLINE
- Journal :
- Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese
- Publication Type :
- Academic Journal
- Accession number :
- 38663567
- Full Text :
- https://doi.org/10.1016/j.hjc.2024.04.006