Analysis of the effectiveness of the latest 4th-generation cryoballoon catheters in pulmonary vein isolation using high-resolution mapping.

Authors :
Gkalapis C
Vlachos K
Papadakis M
Pavleros N
Hippe HJ
Benali K
Bazoukis G
Letsas KP
Frontera A
Jais P
Gotzmann M
Source :
Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese [Hellenic J Cardiol] 2024 Apr 23. Date of Electronic Publication: 2024 Apr 23.
Publication Year :
2024
Publisher :
Ahead of Print

Abstract

Background: Long-term data showed that up to 27% of pulmonary veins are reconnected using cryoballoon ablation. This study aimed to evaluate the efficacy of the latest 4th-generation cryoballoon catheters using ultra high-resolution mapping.<br />Methods: In patients with atrial fibrillation, a standard pulmonary vein isolation (PVI) with the latest 4th-generation cryoballoon catheter (Arctic Front Advance PRO, Medtronic Minneapolis, USA) and the spiral mapping catheter (Achieve Advance, Medtronic, Minneapolis, MN, USA) was performed. Subsequently, high-resolution mapping was achieved using the novel multipolar grid mapping catheter (Advisor HD Grid SE, Abbott Laboratories, USA). Follow-up was obtained after 6 months by means of a 7-day Holter electrocardiogram.<br />Results: In our study, acute PVI was successfully achieved in all 31 patients. The latest 4th-generation cryoballoon catheter is safe in the acute phase of PVI. Additional high-resolution mapping (mean points per map 21,001 ± 4911) using the multipolar grid mapping catheter enabled us to identify residual gaps only in the carina pulmonary vein region; therefore, no additional ablation was performed. Three of 31 patients (10%) presented with atrial arrhythmia recurrence always related with pulmonary vein reconnection; using high-resolution mapping had no additional benefit in identifying pulmonary veins in which reconnection will occur.<br />Conclusion: The utility of additional high-density mapping, facilitated by the HD Grid catheter after PVI with the 4th-generation cryoballoon catheter do not substantiate a discernible advantage over conventional mapping methodologies, particularly, the spiral mapping catheter. Residual carinal conduction was observed in a substantial cohort of patients (48%), highlighting a persistent challenge in achieving complete electrical isolation.<br />Competing Interests: Conflict of interest disclosure MG was a speaker for Abbott, Bristol-Myers Squibb, Novartis, Pfizer, and an advisor for Boehringer Ingelheim.<br /> (Copyright © 2024 Hellenic Society of Cardiology. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
2241-5955
Database :
MEDLINE
Journal :
Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese
Publication Type :
Academic Journal
Accession number :
38663567
Full Text :
https://doi.org/10.1016/j.hjc.2024.04.006