Back to Search Start Over

Temporal Analysis in Outcomes of Long-Term Mechanical Circulatory Support: Retrospective Study.

Authors :
Ondrusek M
Artemiou P
Bezak B
Gasparovic I
By TM
Durdik S
Lesny P
Goncalvesova E
Hulman M
Source :
The Thoracic and cardiovascular surgeon [Thorac Cardiovasc Surg] 2024 Oct; Vol. 72 (7), pp. 521-529. Date of Electronic Publication: 2024 Apr 19.
Publication Year :
2024

Abstract

Background:  Mechanical assist device indications have changed in recent years. Reduced incidence of complications, better survival, and the third generation of mechanical support devices contributed to this change. In this single-center study, we focused on two time periods that are characterized by the use of different types of mechanical support devices, different patient characteristics, and change in the indications.<br />Methods:  The data were processed from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). We retrospectively defined two time intervals to reflect changes in ventricular assist device technology (period 1: 2007-2015; period 2: 2016-20222). A total of 181 patients underwent left ventricular assist device implantation. Device utilization was the following: HeartMate II = 52 (76.4%) and HeartWare = 16 (23.6%) in period 1 and HeartMate II = 2 (1.8%), HeartMate 3 = 70 (61:9%), HeartWare = 29 (25.7%), SynCardia TAH = 10 (8.8%), and BerlinHeart EXCOR = 2 (1.8%) in period 2. The outcomes of the time intervals were analyzed and evaluated.<br />Results:  Survival was significantly higher during the second time period. Multivariate analysis revealed that age and bypass pump time are independent predictors of mortality. Idiopathic cardiomyopathy, bypass time, and the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) score are independent predictors of adverse events. Furthermore, the first period was noted to be at an increased risk of the following adverse events: pump thrombosis, gastrointestinal bleeding, and bleeding events.<br />Conclusion:  Despite the higher risk profile of the patients and persistent challenges, during the second period, there was a significant decrease in mortality and morbidity. The use of the HeartMate 3 device may have contributed to this result.<br />Competing Interests: None declared.<br /> (Thieme. All rights reserved.)

Details

Language :
English
ISSN :
1439-1902
Volume :
72
Issue :
7
Database :
MEDLINE
Journal :
The Thoracic and cardiovascular surgeon
Publication Type :
Academic Journal
Accession number :
38641334
Full Text :
https://doi.org/10.1055/s-0044-1782600