Back to Search
Start Over
Photoreceptor Integrity in MEWDS: Longitudinal Structure-Function Correlations.
- Source :
-
Investigative ophthalmology & visual science [Invest Ophthalmol Vis Sci] 2024 Apr 01; Vol. 65 (4), pp. 28. - Publication Year :
- 2024
-
Abstract
- Purpose: The purpose of this study was to investigate structure-function correlations in multiple evanescent white dot syndrome (MEWDS) using microperimetry (MP) and spectral-domain optical coherence tomography (SD-OCT).<br />Methods: Single-center prospective observational study including 14 eyes from 13 patients with MEWDS monitored over a median of 49.5 days (interquartile range = 29-92 days). Investigations focused on best-corrected visual acuity (BCVA), foveal granularity, and the Photoreceptor Reflectivity Ratio (PRR) as a measure of photoreceptor integrity. MP assessed average retinal threshold sensitivity (RTS) and bivariate contour ellipse area (BCEA) for fixation stability. A linear mixed model was used to test associations and interactions among RTS, time, and clinical variables. A hierarchical linear mixed model was used to analyze structure-function relationships, addressing both individual and location-specific variations.<br />Results: Overall, 2340 MP locations were tested. PRR revealed a transient decrease within 30 days post-presentation, indicative of early photoreceptor disruption, followed by a progressive increase, signaling recovery. Significantly lower foveal sensitivity (RTS = 14.8 ± 7.4 vs. 22.5 ± 4.4 decibel [dB], P = 0.04) and increased fixation spread (63% BCEA = 1.26 ± 0.97 vs. 0.48 ± 0.35 deg2, P = 0.06) were noted in eyes with foveal granularity compared to those without. A significant increase in RTS was demonstrated over time (0.066 dB/day, P < 0.001), with a central-to-peripheral gradient of improvement. The interaction between follow-up time and baseline BCVA (P < 0.001) indicated more rapid improvement in eyes with worse initial vision. There was a robust, nonlinear association between PRR and RTS across all tested locations (P < 0.001), becoming asymptotic for sensitivity losses exceeding 20 dB.<br />Conclusions: Photoreceptor reflectivity accurately aligned with visual function in MEWDS on longitudinal examinations. The central-to-peripheral gradient of improvement may suggest specific vulnerabilities underlying the area around the disc.
Details
- Language :
- English
- ISSN :
- 1552-5783
- Volume :
- 65
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- Investigative ophthalmology & visual science
- Publication Type :
- Academic Journal
- Accession number :
- 38630674
- Full Text :
- https://doi.org/10.1167/iovs.65.4.28