Back to Search Start Over

DeepFLAIR: A neural network approach to mitigate signal and contrast loss in temporal lobes at 7 Tesla FLAIR images.

Authors :
Uher D
Drenthen GS
Poser BA
Hofman PAM
Wagner LG
van Lanen RHGJ
Hoeberigs CM
Colon AJ
Schijns OEMG
Jansen JFA
Backes WH
Source :
Magnetic resonance imaging [Magn Reson Imaging] 2024 Jul; Vol. 110, pp. 57-68. Date of Electronic Publication: 2024 Apr 15.
Publication Year :
2024

Abstract

Background and Purpose: Higher magnetic field strength introduces stronger magnetic field inhomogeneities in the brain, especially within temporal lobes, leading to image artifacts. Particularly, T2-weighted fluid-attenuated inversion recovery (FLAIR) images can be affected by these artifacts. Here, we aimed to improve the FLAIR image quality in temporal lobe regions through image processing of multiple contrast images via machine learning using a neural network.<br />Methods: Thirteen drug-resistant MR-negative epilepsy patients (age 29.2 ± 9.4y, 5 females) were scanned on a 7 T MRI scanner. Magnetization-prepared (MP2RAGE) and saturation-prepared with 2 rapid gradient echoes, multi-echo gradient echo with four echo times, and the FLAIR sequence were acquired. A voxel-wise neural network was trained on extratemporal-lobe voxels from the acquired structural scans to generate a new FLAIR-like image (i.e., deepFLAIR) with reduced temporal lobe inhomogeneities. The deepFLAIR was evaluated in temporal lobes through signal-to-noise (SNR), contrast-to-noise (CNR) ratio, the sharpness of the gray-white matter boundary and joint-histogram analysis. Saliency mapping demonstrated the importance of each input image per voxel.<br />Results: SNR and CNR in both gray and white matter were significantly increased (p < 0.05) in the deepFLAIR's temporal ROIs, compared to the FLAIR. The gray-white matter boundary sharpness was either preserved or improved in 10/13 right-sided temporal regions and was found significantly increased in the ROIs. Multiple image contrasts were influential for the deepFLAIR reconstruction with the MP2RAGE second inversion image being the most important.<br />Conclusions: The deepFLAIR network showed promise to restore the FLAIR signal and reduce contrast attenuation in temporal lobe areas. This may yield a valuable tool, especially when artifact-free FLAIR images are not available.<br /> (Copyright © 2023. Published by Elsevier Inc.)

Details

Language :
English
ISSN :
1873-5894
Volume :
110
Database :
MEDLINE
Journal :
Magnetic resonance imaging
Publication Type :
Academic Journal
Accession number :
38621552
Full Text :
https://doi.org/10.1016/j.mri.2024.04.013