Back to Search
Start Over
Impact of atrial fibrillation on 1-year outcome in patients with implantable cardioverter defibrillator or cardiac resynchronization therapy with defibrillator: results from the German DEVICE Registry.
- Source :
-
Journal of thoracic disease [J Thorac Dis] 2024 Mar 29; Vol. 16 (3), pp. 1825-1835. Date of Electronic Publication: 2024 Mar 27. - Publication Year :
- 2024
-
Abstract
- Background: Atrial fibrillation (AF) is a cardiac arrhythmia frequently documented in patients requiring implantable cardioverter defibrillators (ICDs) and/or cardiac resynchronization therapy with defibrillator (CRT-D). Patients with diagnosed AF at the point of ICD or CRT-D implantation may have an impaired follow-up outcome.<br />Methods: The German DEVICE I-II registry is a nationwide prospective multicentre database of patients implanted with ICD and CRT-D with clinical follow-up data. We analysed a 1-year follow up of implanted patients with AF and with sinus rhythm (SR).<br />Results: A total of 4,929 ICD/CRT patients are included in the present analysis: 946 (19.2%) were in AF and 3,983 (80.8%) were SR at time of device implantation. AF patients had a significantly more comorbid profile including older age {72 [interquartile range (IQR), 66-77] vs. 66 (IQR, 56-73) years; P<0.001}, and higher rate of patients with left ventricular ejection fraction <30% (68.2% vs. 61.0%; P<0.001), peripheral artery disease (4.5% vs. 2.7%; P=0.002), diabetes (33.6% vs. 25.5%; P<0.001), hypertension (58.4% vs. 51.1%; P<0.001) and renal failure (22.6% vs. 15.3%; P<0.001). The intra-hospital complication rate was 4.3% in the AF and 3.6% in the SR group (P=0.38). In 1-year follow-up AF patients experienced a significantly higher rate of defibrillator shocks (25% vs. 15.3%; P<0.001). One-year estimated mortality was 10.8% in the AF and 5.9% in the SR group (P<0.001), while estimated 1-year major adverse cardiac and cerebrovascular events (MACCE) rate was 11.2% vs. 7.0% (P<0.001). The effects of AF on electrical shocks and mortality persisted after adjusting for age, sex, advanced New York Heart Association (NYHA) class, severely impaired left ventricular ejection fraction (LVEF), coronary artery disease (CAD), chronic obstructive pulmonary disease (COPD), diabetes mellitus (DM), chronic renal failure (CRF), QRS duration, and type of indication for electronic device implantation.<br />Conclusions: Our clinical data on an extended cohort of contemporary patients confirm the significant impact of AF, and its associated comorbidities, upon mortality and major adverse events after implantation of ICD/CRT.<br />Competing Interests: Conflicts of Interest: All authors have completed the ICMJE uniform disclosure form (available at https://jtd.amegroups.com/article/view/10.21037/jtd-23-274/coif). G.D. serves as an unpaid editorial board member of Journal of Thoracic Disease from February 2023 to January 2025. H.I. received an institutional research grant from Boston Scientific. J.K. received honoraria for lectures and travel grants from Abbott, Boston Scientific and Biotronik. The other authors have no conflicts of interest to declare.<br /> (2024 Journal of Thoracic Disease. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 2072-1439
- Volume :
- 16
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Journal of thoracic disease
- Publication Type :
- Academic Journal
- Accession number :
- 38617758
- Full Text :
- https://doi.org/10.21037/jtd-23-274