Usefulness of double plate fixation after failed ORIF for clavicle shaft fracture.
- Source :
-
European journal of orthopaedic surgery & traumatology : orthopedie traumatologie [Eur J Orthop Surg Traumatol] 2024 Jul; Vol. 34 (5), pp. 2373-2377. Date of Electronic Publication: 2024 Apr 10. - Publication Year :
- 2024
-
Abstract
- Purpose: We aimed to evaluate the clinical and radiological outcomes of double plate fixation for failed clavicle shaft fracture surgery.<br />Materials and Methods: We analyzed 14 patients who underwent double plate fixation due to plate failure after clavicle shaft fracture surgery from March 2016 to March 2021. The study used 3.5 mm locking compression plates for superior clavicle and anterior reconstruction in all patients. In addition, moldable allograft bone was used to fill the bone defect. Clinical and radiological evaluation was performed immediately, at 2 and 4 weeks, and 3, 6, 9, and 12 months postoperatively. The visual analog scale (VAS), University of California at Los Angeles (UCLA) shoulder scale, and American Shoulder and Elbow Surgeons (ASES) scores and range of motion of the shoulder were evaluated as clinical results. For radiological evaluation, anteroposterior, caudal, and cephalad views of both clavicles were used. Successful bone union was defined as complete adjoining of the fracture site through callus formation.<br />Results: Successful bone union was achieved in all patients, and the mean time to bone union was 16.7 ± 1.2 weeks (range, 12-24 weeks). Statistically significant improvement in forward flexion and external and internal rotation was observed from 135.5° ± 6.3, 45.2° ± 5.3, and 13° ± 2.3 preoperatively to 157.0° ± 9.3, 68.7° ± 6.3, and 9.8° ± 3.1 at the final follow-up, respectively. The VAS score improved from an average of 6.2 ± 2.8 preoperatively to 1.3 ± 0.7 at the final follow-up, which was statistically significant (P = 0.018). In addition, the ASES score significantly increased from a mean of 52.1 ± 6.3 points preoperatively to 83.6 ± 7.8 points at the final follow-up (P = 0.001). The average UCLA shoulder score was 16.7 ± 1.4 and 31.4 ± 2.2 points preoperatively and at the final follow-up, respectively, which was statistically significant (P = 0.001).<br />Conclusion: Double plate fixation has shown good results after failed open reduction and internal fixation (ORIF) for clavicle shaft fractures. Therefore, in complicated situations after ORIF, double plate fixation is considered a surgical treatment option.<br /> (© 2024. The Author(s).)
- Subjects :
- Humans
Female
Male
Adult
Middle Aged
Fracture Healing
Retrospective Studies
Treatment Failure
Open Fracture Reduction methods
Bone Transplantation methods
Reoperation
Young Adult
Clavicle injuries
Clavicle surgery
Clavicle diagnostic imaging
Bone Plates
Fracture Fixation, Internal methods
Fracture Fixation, Internal instrumentation
Fractures, Bone surgery
Fractures, Bone diagnostic imaging
Range of Motion, Articular
Subjects
Details
- Language :
- English
- ISSN :
- 1432-1068
- Volume :
- 34
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- European journal of orthopaedic surgery & traumatology : orthopedie traumatologie
- Publication Type :
- Academic Journal
- Accession number :
- 38598169
- Full Text :
- https://doi.org/10.1007/s00590-024-03927-5