Back to Search Start Over

Clinical Outcomes and Graft Resorption After Metal-Free Bone Block Suture Tape Cerclage Fixation for Recurrent Anterior Shoulder Instability: A Computed Tomography Analysis.

Authors :
Hachem AI
Diaz-Apablaza E
Molina-Creixell A
Ruis X
Videla S
Luis Agulló J
Source :
The American journal of sports medicine [Am J Sports Med] 2024 May; Vol. 52 (6), pp. 1472-1482. Date of Electronic Publication: 2024 Apr 08.
Publication Year :
2024

Abstract

Background: Glenoid reconstruction with a bone block for anterior glenoid bone loss (GBL) has shown excellent outcomes. However, fixation techniques that require metal implants are associated with metal-related complications and bone graft resorption.<br />Hypothesis: Arthroscopic glenoid reconstruction using a tricortical iliac crest bone graft (ICBG) and metal-free suture tape cerclage fixation can safely and effectively restore the glenoid surface area in patients with recurrent anterior shoulder instability and anterior GBL.<br />Study Design: Case series; Level of evidence, 4.<br />Methods: Adult patients (≥18 years) of both sexes with recurrent anterior shoulder instability and anterior GBL ≥15% were enrolled. These patients underwent arthroscopic glenoid reconstruction with ICBGs and metal-free suture tape cerclage fixation. The effectiveness and clinical outcomes with this technique were evaluated at 24 months using functional scores. Resorption of the graft articular surface was assessed by computed tomography, with the graft surface divided into 6 square areas aligned in 2 columns. Descriptive analysis was conducted.<br />Results: A total of 23 consecutive patients met inclusion criteria (22 male, 1 female; mean age, 30.5 ± 7.9 years). The mean preoperative GBL was 19.7% ± 3.4%, and there were 15 allograft and 8 autograft ICBGs. All patients exhibited graft union at 3 months. The median follow-up was 38.5 months (interquartile range, 24-45 months). The Western Ontario Shoulder Instability Index, Rowe, Constant-Murley, and Subjective Shoulder Value scores improved from preoperatively (35.1%, 24.8, 83.1, and 30.9, respectively) to postoperatively (84.7%, 91.1, 96.0, and 90.9, respectively) ( P < .001). No differences in clinical scores were observed between the graft types. One surgical wound infection was reported, and 2 patients (8.7% [95% CI, 2.4%-26.8%]) required a reoperation. The mean overall glenoid surface area increased from 80.3% ± 3.5% to 117.0% ± 8.3% immediately after surgery before subsequently reducing to 98.7% ± 6.2% and 95.0% ± 5.7% at 12 and 24 months, respectively ( P < .001). The mean graft resorption rate was 18.1% ± 7.9% in the inner column and 80.3% ± 22.4% in the outer column. Additionally, 3 patients treated with an allograft (20.0% [95% CI, 7.1%-45.2%]), including the 2 with clinical failures, exhibited complete graft resorption at the last follow-up.<br />Conclusion: Arthroscopic glenoid reconstruction using an ICBG and metal-free suture tape cerclage fixation was safe and effective, yielding excellent clinical outcomes. Resorption of the graft articular surface predominantly affected the nonloaded areas beyond the best-fit circle perimeter.<br />Competing Interests: One or more of the authors has declared the following potential conflict of interest or source of funding: A.H. has a patent with Arthrex for the bone block suture tape cerclage fixation method. AOSSM checks author disclosures against the Open Payments Database (OPD). AOSSM has not conducted an independent investigation on the OPD and disclaims any liability or responsibility relating thereto.

Details

Language :
English
ISSN :
1552-3365
Volume :
52
Issue :
6
Database :
MEDLINE
Journal :
The American journal of sports medicine
Publication Type :
Academic Journal
Accession number :
38590203
Full Text :
https://doi.org/10.1177/03635465241236179