Back to Search Start Over

Performance of a novel eight-color flow cytometry panel for measurable residual disease assessment of chronic lymphocytic leukemia.

Authors :
Chen X
Chen X
Zhao S
Shi Y
Zhang N
Guo Z
Qiao C
Jin H
Zhu L
Zhu H
Li J
Wu Y
Source :
Cytometry. Part B, Clinical cytometry [Cytometry B Clin Cytom] 2024 May; Vol. 106 (3), pp. 181-191. Date of Electronic Publication: 2024 Mar 27.
Publication Year :
2024

Abstract

Background: Measurable residual disease (MRD) is an important prognostic indicator of chronic lymphocytic leukemia (CLL). Different flow cytometric panels have been developed for the MRD assessment of CLL in Western countries; however, the application of these panels in China remains largely unexplored.<br />Methods: Owing to the requirements for high accuracy, reproducibility, and comparability of MRD assessment in China, we investigated the performance of a flow cytometric approach (CD45-ROR1 panel) to assess MRD in patients with CLL. The European Research Initiative on CLL (ERIC) eight-color panel was used as the "gold standard."<br />Results: The sensitivity, specificity, and concordance rate of the CD45-ROR1 panel in the MRD assessment of CLL were 100% (87/87), 88.5% (23/26), and 97.3% (110/113), respectively. Two of the three inconsistent samples were further verified using next-generation sequencing. In addition, the MRD results obtained from the CD45-ROR1 panel were positively associated with the ERIC eight-color panel results for MRD assessment (R = 0.98, p < 0.0001). MRD detection at low levels (≤1.0%) demonstrated a smaller difference between the two methods (bias, -0.11; 95% CI, -0.90 to 0.68) than that at high levels (>1%). In the reproducibility assessment, the bias was smaller at three data points (within 24, 48, and 72 h) in the CD45-ROR1 panel than in the ERIC eight-color panel. Moreover, MRD levels detected using the CD45-ROR1 panel for the same samples from different laboratories showed a strong statistical correlation (R = 0.99, p < 0.0001) with trivial interlaboratory variation (bias, 0.135; 95% CI, -0.439 to 0.709). In addition, the positivity rate of MRD in the bone marrow samples was higher than that in the peripheral blood samples.<br />Conclusions: Collectively, this study demonstrated that the CD45-ROR1 panel is a reliable method for MRD assessment of CLL with high sensitivity, reproducibility, and reliability.<br /> (© 2024 The Authors. Cytometry Part B: Clinical Cytometry published by Wiley Periodicals LLC on behalf of International Clinical Cytometry Society.)

Details

Language :
English
ISSN :
1552-4957
Volume :
106
Issue :
3
Database :
MEDLINE
Journal :
Cytometry. Part B, Clinical cytometry
Publication Type :
Academic Journal
Accession number :
38535092
Full Text :
https://doi.org/10.1002/cyto.b.22170