Utility of superior augments in reverse shoulder arthroplasty (Exactech, Equinoxe GPS) without significant glenoid deformity.
- Source :
-
Journal of shoulder and elbow surgery [J Shoulder Elbow Surg] 2024 Oct; Vol. 33 (10), pp. 2196-2201. Date of Electronic Publication: 2024 Mar 20. - Publication Year :
- 2024
-
Abstract
- Background: Superior augment use may help avoid superior tilt while minimizing removal of inferior glenoid bone. Therefore, our goal was to compare superior augments vs. no-augment baseplates in reverse shoulder arthroplasty (RSA) for patients with rotator cuff dysfunction and no significant superior glenoid erosion.<br />Methods: A multicenter retrospective analysis of 145 patients who underwent RSA with intraoperative navigation (Equinoxe GPS; Exactech) and 3-year follow-up (mean 32 months' follow-up, range 20-61 months) who had preoperative superior inclination less than 10° and retroversion less than 15°. Patient demographics, radiographic measurements, surgical characteristics, patient-reported outcomes at preoperative and postoperative visit closest to 3 years, and adverse events at final follow-up were obtained. Operative time, planned inclination, and planned version of the baseplate were obtained. χ <superscript>2</superscript> test was used to compare categorical variables, and Student t test was used to compare the augment and no-augment cohorts.<br />Results: The study population consisted of 54 superior augment patients and 91 no-augment patients. The augment cohort had lower body mass index (27.2 vs. 29.4, P = .023) and higher native superior inclination (5.9° vs. 1.4°, P < .001). No difference between the augment and no-augment cohorts was found regarding age (P = .643), gender (P = .314), medical comorbidities (P > .05), surgical indication (P = .082), and native glenoid version (P = .564). The augment cohort had higher internal rotation score (4.6 vs. 3.9, P = .023), and all remaining range of motion (ROM) and patient-reported outcomes (PROs) preoperatively were not significantly different. At final follow-up, active ROM in all planes was not different between the cohorts. Regarding PROs, the postoperative Shoulder Arthroplasty Smart score was significantly higher (78.0 vs. 73.6, P = .042), and American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form score trended toward higher (83.6 vs. 77.5, P = .063) in the augment cohort. The augment cohort had a significantly lower proportion of patients who planned to have superior baseplate tilt (1.9% vs. 14.3%, P = .012) and had greater mean inclination correction (6.3° vs. 1.3°, P < .001), compared with the no-augment cohort. Adverse events were rare, and there was no significant difference found between the augment and no-augment cohorts (5.6% vs. 3.3%, P = .509).<br />Discussion: Superior augmented baseplate in RSA with minimal superior glenoid erosion is associated with similar ROM and adverse events with somewhat improved postoperative PROs compared with nonaugmented baseplates at the 3-year follow-up. Additionally, superior augments resulted in a greater proportion of baseplates planned to avoid superior tilt, and trended toward shorter operative times. Further investigation of long-term glenoid baseplate loosening is imperative to fully understand the cost-effectiveness of superior augments in the setting of minimal glenoid deformity.<br /> (Copyright © 2024 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1532-6500
- Volume :
- 33
- Issue :
- 10
- Database :
- MEDLINE
- Journal :
- Journal of shoulder and elbow surgery
- Publication Type :
- Academic Journal
- Accession number :
- 38514007
- Full Text :
- https://doi.org/10.1016/j.jse.2024.01.047