Back to Search Start Over

Four-Color ImmunoSpot ® Assays Requiring Only 1-3 mL of Blood Permit Precise Frequency Measurements of Antigen-Specific B Cells-Secreting Immunoglobulins of All Four Classes and Subclasses.

Authors :
Yao L
Becza N
Maul-Pavicic A
Chepke J
Kirchenbaum GA
Lehmann PV
Source :
Methods in molecular biology (Clifton, N.J.) [Methods Mol Biol] 2024; Vol. 2768, pp. 251-272.
Publication Year :
2024

Abstract

The B lymphocyte response can encompass four immunoglobulin (Ig) classes and four IgG subclasses, each contributing fundamentally different effector functions. Production of the appropriate Ig class/subclass is critical for both successful host defense and avoidance of immunopathology. The assessment of an antigen-specific B cell response, including its magnitude and Ig class/subclass composition, is most often confined to the antibodies present in serum and other biological fluids and neglects monitoring of the memory B cell (B <subscript>mem</subscript> ) compartment capable of mounting a faster and more efficient antibody response following antigen reencounter. Here, we describe how the frequency and Ig class and IgG subclass use of an antigen-specific B <subscript>mem</subscript> repertoire can be determined with relatively little labor and cost, requiring only 8 × 10 <superscript>5</superscript> freshly isolated peripheral blood mononuclear cells (PBMC), or if additional cryopreservation and polyclonal stimulation is necessary, 3 × 10 <superscript>6</superscript> PBMC per antigen. To experimentally validate such cell saving assays, we have documented that frequency measurements of antibody-secreting cells (ASC) yield results indistinguishable from those of enzymatic (ELISPOT) or fluorescent (FluoroSpot) versions of the ImmunoSpot <superscript>®</superscript> assay, including when the latter are detected in alternative fluorescent channels. Moreover, we have shown that frequency calculations that are based on linear regression analysis of serial PBMC dilutions using a single well per dilution step are as accurate as those performed using replicate wells. Collectively, our data highlight the capacity of multiplexed B cell FluoroSpot assays in conjunction with serial dilutions to significantly reduce the PBMC requirement for detailed assessment of antigen-specific B cells. The protocols presented here allow GLP-compliant high-throughput measurements which should help to introduce high-dimensional B <subscript>mem</subscript> characterization into the standard immune monitoring repertoire.<br /> (© 2024. The Author(s).)

Details

Language :
English
ISSN :
1940-6029
Volume :
2768
Database :
MEDLINE
Journal :
Methods in molecular biology (Clifton, N.J.)
Publication Type :
Academic Journal
Accession number :
38502398
Full Text :
https://doi.org/10.1007/978-1-0716-3690-9_15