Back to Search Start Over

An Exploratory Pilot Study on the Application of Radiofrequency Ablation for Atrial Fibrillation Guided by Computed Tomography-Based 3D Printing Technology.

Authors :
Yue JY
Li PC
Li MX
Wu QW
Liang CH
Chen J
Zhu ZP
Li PH
Dou WG
Gao JB
Source :
Journal of imaging informatics in medicine [J Imaging Inform Med] 2024 Oct; Vol. 37 (5), pp. 2025-2037. Date of Electronic Publication: 2024 Mar 15.
Publication Year :
2024

Abstract

Radiofrequency ablation (RFA) is the treatment of choice for atrial fibrillation (AF). Additionally, the utilization of 3D printing for cardiac models offers an in-depth insight into cardiac anatomy and cardiovascular diseases. The study aims to evaluate the clinical utility and outcomes of RFA following in vitro visualization of the left atrium (LA) and pulmonary vein (PV) structures via 3D printing (3DP). Between November 2017 and April 2021, patients who underwent RFA at the First Affiliated Hospital of Xinxiang Medical University were consecutively enrolled and randomly allocated into two groups: the 3DP group and the control group, in a 1:1 ratio. Computed tomography angiography (CTA) was employed to capture the morphology and diameter of the LA and PV, which facilitated the construction of a 3D entity model. Additionally, surgical procedures were simulated using the 3D model. Parameters such as the duration of the procedure, complications, and rates of RFA recurrence were meticulously documented. Statistical analysis was performed using the t-test or Mann-Whitney U test to evaluate the differences between the groups, with a P-value of less than 0.05 considered statistically significant. In this study, a total of 122 patients were included, with 53 allocated to the 3DP group and 69 to the control group. The analysis of the morphological measurements of the LA and PV taken from the workstation or direct entity measurement showed no significant difference between the two groups (P > 0.05). However, patients in the 3DP group experienced significantly shorter RFA times (97.03 ± 28.39 compared to 120.51 ± 44.76 min, t = 3.05, P = 0.003), reduced duration of radiation exposure (2.55 [interquartile range 2.01, 3.24] versus 3.20 [2.28, 3.91] min, Z = 3.23, P < 0.001), and shorter modeling times (7.68 ± 1.03 compared to 8.89 ± 1.45 min, t = 5.38, P < 0.001). 3DP technology has the potential to enhance standard RFA practices by reducing the time required for intraoperative interventions and exposure to radiation.<br /> (© 2024. The Author(s) under exclusive licence to Society for Imaging Informatics in Medicine.)

Details

Language :
English
ISSN :
2948-2933
Volume :
37
Issue :
5
Database :
MEDLINE
Journal :
Journal of imaging informatics in medicine
Publication Type :
Academic Journal
Accession number :
38491235
Full Text :
https://doi.org/10.1007/s10278-024-01081-2