Back to Search
Start Over
Efficacy and safety of the Aria pulmonary endovascular device in pulmonary hypertension.
- Source :
-
European journal of heart failure [Eur J Heart Fail] 2024 Mar; Vol. 26 (3), pp. 686-694. Date of Electronic Publication: 2024 Mar 13. - Publication Year :
- 2024
-
Abstract
- Aims: A common feature of various forms of pulmonary hypertension (PH) is progressive decline of pulmonary arterial compliance (C <subscript>PA</subscript> ), which correlates with reduced survival. In this acute study, we evaluated feasibility, safety and haemodynamic performance of the Aria pulmonary endovascular device in patients with PH associated with left heart disease (PH-LHD) and chronic lung disease (PH-CLD).<br />Methods and Results: Eight patients with PH-LHD and 10 patients with PH-CLD were included in this study. The device was placed in the main pulmonary artery via the right femoral vein and was connected by a catheter to a gas-filled reservoir outside the body. During systole, gas shifts from the balloon to the reservoir, leading to deflation of the balloon. In diastole, the gas returns from the reservoir to the balloon, leading to balloon inflation and enhancing diastolic blood flow to the distal pulmonary capillary bed. Haemodynamics were assessed at baseline, and again with device off, device on and device off. The primary safety endpoint was the incidence of serious adverse events through 30 days after the procedure. No complications or investigational device-related serious adverse events occurred. Device activation in PH-LHD and PH-CLD patients decreased pulmonary arterial pulse pressure by 5.6 ± 4.2 mmHg (-12%; p = 0.003) and 4.2 ± 2.2 mmHg (-11%; p < 0.001), increased C <subscript>PA</subscript> by 0.4 ± 0.2 ml/mmHg (+23%; p = 0.004) and 0.4 ± 0.3 ml/mmHg (+25%; p = 0.001), and increased right ventricular-to-pulmonary vascular (RV-PV) coupling by 0.24 ± 0.18 (+40%; p = 0.012) and 0.11 ± 0.07 (+21%; p = 0.001), respectively.<br />Conclusions: Temporary implantation of the Aria endovascular device was feasible and safe. Device activation resulted in acute improvement of C <subscript>PA</subscript> and RV-PV coupling.<br /> (© 2024 The Authors. European Journal of Heart Failure published by John Wiley & Sons Ltd on behalf of European Society of Cardiology.)
Details
- Language :
- English
- ISSN :
- 1879-0844
- Volume :
- 26
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- European journal of heart failure
- Publication Type :
- Academic Journal
- Accession number :
- 38481353
- Full Text :
- https://doi.org/10.1002/ejhf.3187