Back to Search Start Over

A multicentre evaluation of the NG-test DetecTool OXA-23 for the rapid detection of OXA-23 carbapenemase directly from blood cultures.

Authors :
Vasilakopoulou A
Naas T
Gonzalez C
Vila J
Szabo D
Riccobono E
Kamotsay K
Reissier S
Berbel D
Aszalos AZ
Rosenmoller M
Stankov-Puges M
Georgiou PC
Vourli S
Volland H
Pournaras S
Source :
JAC-antimicrobial resistance [JAC Antimicrob Resist] 2024 Mar 07; Vol. 6 (2), pp. dlae029. Date of Electronic Publication: 2024 Mar 07 (Print Publication: 2024).
Publication Year :
2024

Abstract

Objectives: A multicentre study evaluating NG-Test DetecTool OXA-23 for the detection of OXA-23 carbapenemase directly from positive blood cultures (PBCs).<br />Methods: The NG-Test DetecTool OXA-23 is an immunoassay that integrates a sample preparation device. We evaluated NG-Test DetecTool OXA-23 on 189 spiked and 126 clinical PBCs. The clinical samples' standard-of-care procedure consisted of bacterial identification from the first day of positivity by MALDI-TOF MS, conventional culture and antimicrobial susceptibility testing. The immunoassay results were verified molecularly. The strains used for the spiked samples consisted of well-characterized Acinetobacter baumannii and Proteus mirabilis strains.<br />Results: The NG-Test DetecTool OXA-23 was evaluated on 315 PBCs and revealed sensitivity of 100% (95% CI: 98.21%-100.00%) and specificity of 100% (95% CI: 96.73%-100.00%). It provided 204 true-positive results for OXA-23 in 196 bottles with carbapenem-resistant A. baumannii (CRAB) and 8 bottles with carbapenem-resistant P. mirabilis and also provided 111 true-negative results. There were no false-positive and no false-negative results. Among the 315 PBCs studied, 83 clinical blood cultures collected in the ICU of a Greek university hospital, which were tested prospectively, all yielded CRAB, and OXA-23 was correctly detected in all samples from the first day of positivity using the NG-Test DetecTool OXA-23.<br />Conclusions: The NG-Test DetecTool OXA-23 has exhibited excellent sensitivity and specificity for OXA-23 detection in PBCs and can provide valuable information for appropriate selection of antibiotic therapy and early implementation of infection control measures.<br /> (© The Author(s) 2024. Published by Oxford University Press on behalf of British Society for Antimicrobial Chemotherapy.)

Details

Language :
English
ISSN :
2632-1823
Volume :
6
Issue :
2
Database :
MEDLINE
Journal :
JAC-antimicrobial resistance
Publication Type :
Academic Journal
Accession number :
38455379
Full Text :
https://doi.org/10.1093/jacamr/dlae029