Back to Search Start Over

Strategies to improve atrioventricular synchrony in patients with a Micra AV leadless pacemaker.

Authors :
Garweg C
Breitenstein A
Clémenty N
De Asmundis C
Iacopino S
Johansen JB
Sharman D
Theis C
Prat XV
Winter S
Reichlin T
Source :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology [Europace] 2024 Mar 01; Vol. 26 (3).
Publication Year :
2024

Abstract

The second generation of transcatheter pacing systems, called Micra AV, can provide atrioventricular (AV) synchronous pacing via a new pacing algorithm relying on sensing mechanical atrial contraction. Several novel programming parameters were introduced to enable AV synchronous pacing, including an A3 window and A4 window as well as a conduction mode switch and an activity mode switch. In addition to several automated features, manual programming optimization of some of the novel parameters is key to improving AV synchrony. A solid knowledge of the features and their programming is essential for electrophysiologists implanting or following patients with Micra AV devices. Differences in programming optimization might partially explain the high variability of AV synchrony published in real-world data reports. This article reviews the key programming parameters of Micra AV. Subsequently, optimal programming recommendations for defined patient profiles are presented. Those were established by consensus within an expert panel comprised of 11 European electrophysiologists from high-volume Micra AV centres. The patient profiles were (1) high degree AV block and slow sinus rhythm; (2) high degree AV block and fast sinus rhythm; and (3) intermittent AV block. The panel recommended to evaluate the mechanical atrial activity on transthoracic echocardiography prior to implant. It was also agreed that Auto A3 Threshold and Tracking Check should be turned off in all patients, AV conduction mode switch should be turned off in all patients with high degree AV block, and the lower rate should be programmed to 50 bpm with exceptions based on individual clinical assessment. Future studies will be useful to evaluate the strength of those recommendations to improve the AV synchrony.<br />Competing Interests: Conflict of interest: C.G. receives consultant and/or speaker fees and research grants from Abbot, Biotronik, and Medtronic. A.B. has received consultant and/or speaker fees from Abbott, Bayer Healthcare, Biosense Webster, Biotronik, Boston Scientific, Bristol-Myers Squibb, Cook Medical, Daiichi Sankyo, Medtronic, Pfizer, and Spectranetics/Philips. N.C. receives consulting fees from Medtronic. C.D.A. received research grants from Biotronik, Medtronic, Abbott, LivaNova, Boston Scientific, AtriCure, Philips, and Acutus; and received compensation for teaching purposes and proctoring from Medtronic, Abbott, Biotronik, Livanova, Boston Scientific, Atricure, Acutus Medical, and Daiichi Sankyo. J.B.J. receives consulting fees from Medtronic. T.R. receives research grants from the Swiss National Science Foundation, the Swiss Heart Foundation, and the Sitem Insel support fund; speaker/consulting honoraria or travel support from Abbott/SJM, Bayer, Biosense Webster, Biotronik, Boston Scientific, Daiichi Sankyo, Farapulse, Medtronic, and Pfizer-BMS; support for the institution’s fellowship programme from Abbott/SJM, Biosense Webster, Biotronik, Boston Scientific, and Medtronic. All remaining authors have declared no conflicts of interest.<br /> (© The Author(s) 2024. Published by Oxford University Press on behalf of the European Society of Cardiology.)

Details

Language :
English
ISSN :
1532-2092
Volume :
26
Issue :
3
Database :
MEDLINE
Journal :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
Publication Type :
Academic Journal
Accession number :
38449430
Full Text :
https://doi.org/10.1093/europace/euae060