Back to Search Start Over

SYNERGY-Everolimus-Eluting Stent With a Bioabsorbable Polymer in ST-Elevation Myocardial Infarction: CLEAR SYNERGY OASIS-9 Registry.

Authors :
Jolly SS
Lee SF
Mian R
Kedev S
Lavi S
Moreno R
Montalescot G
Hillani A
Henry TD
Asani V
Storey RF
Silvain J
Spratt JCS
d'Entremont MA
Stankovic G
Zafirovska B
Natarajan MK
Sabate M
Shreenivas S
Pinilla-Echeverri N
Sheth T
Altisent OA
Ribas N
Skuriat E
Tyrwhitt J
Mehta SR
Source :
The American journal of cardiology [Am J Cardiol] 2024 Jun 01; Vol. 220, pp. 111-117. Date of Electronic Publication: 2024 Mar 04.
Publication Year :
2024

Abstract

Our objective was to evaluate the clinical effectiveness of the SYNERGY stent (Boston Scientific Corporation, Marlborough, Massachusetts) in patients with ST-elevation myocardial infarction (STEMI). The only drug-eluting stent approved for treatment of STEMI by the Food and Drug Administration is the Taxus stent (Boston Scientific) which is no longer commercially available, so further data are needed. The CLEAR (Colchicine and spironolactone in patients with myocardial infarction) SYNERGY stent registry was embedded into a larger randomized trial of patients with STEMI (n = 7,000), comparing colchicine versus placebo and spironolactone versus placebo. The primary outcome for the SYNERGY stent registry is major adverse cardiac events (MACE) as defined by cardiovascular death, recurrent MI, or unplanned ischemia-driven target vessel revascularization within 12 months. We estimated a MACE rate of 6.3% at 12 months after primary percutaneous coronary intervention for STEMI based on the Thrombectomy vs percutaneous coronary intervention alone in STEMI (TOTAL) trial. Success was defined as upper bound of confidence interval (CI) to be less than the performance goal of 9.45%. Overall, 733 patients were enrolled from 8 countries with a mean age 60 years, 19.4% diabetes mellitus, 41.3% anterior MI, and median door-to-balloon time of 72 minutes. The MACE rate was 4.8% (95% CI 3.2 to 6.3%) at 12 months which met the success criteria against performance goal of 9.45%. The rates of cardiovascular death, recurrent MI, or target vessel revascularization were 2.7%, 1.9%, 1.0%, respectively. The rates of acute definite stent thrombosis were 0.3%, subacute 0.4%, late 0.4%, and cumulative stent thrombosis of 1.1% at 12 months. In conclusion, the SYNERGY stent in STEMI performed well and was successful compared with the performance goal based on previous trials.<br />Competing Interests: Declaration of competing interest Dr. Jolly reports financial support was provided by Boston Scientific Corp. Dr. Jolly reports financial support was provided by Canadian Institutes of Health Research. Dr. Sabate reports consulting for Abbott Vascular and iVascular. Natalia Pinilla-Echeverri reports consulting for Conavi, Amgen, Bayer, and Novartis; financial support provided by Abbott Vascular; and an advisory board position at Philips. Dr. Mehta reports consulting for and financial support provided by Abbott, Amgen, Bristol-Myers Squibb, HLS Therapeutics, Janssen, Merck, Novartis, and Novo Nordisk. The remaining authors have no competing interests to declare.<br /> (Copyright © 2024 The Authors. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1879-1913
Volume :
220
Database :
MEDLINE
Journal :
The American journal of cardiology
Publication Type :
Academic Journal
Accession number :
38447893