Back to Search Start Over

AmpFire HPV and ScreenFire RS HPV validation trial.

Authors :
Hou J
Belinson JL
Du H
Li C
Zhang W
Zhang L
Zhang Y
Qu X
Wu R
Source :
American journal of clinical pathology [Am J Clin Pathol] 2024 Jun 03; Vol. 161 (6), pp. 535-542.
Publication Year :
2024

Abstract

Objectives: The human papillomavirus (HPV) screening assays from Atila Biosystems, including the new AmpFire (14 type) and ScreenFire RS (13 type), were subjected to a series of validation tests.<br />Methods: We used a set of samples from the Chinese Multi-Site Screening Trial (previously tested with cobas 4800 and the next-generation SeqHPV) to satisfy Meijer's criteria for clinical end-point validation. We selected 556 self-collected specimens composed of 273 high-risk HPV (hrHPV) positives and 283 hrHPV negatives on the cobas 4800 and SeqHPV. Of the 273 hrHPV-positive cases, 108 had a disease end point of cervical intraepithelial neoplasia grade 2 (CIN2) or higher, including 47 with cervical intraepithelial neoplasia grade 3 (CIN3+) or higher. We simulated the VALGENT framework for inter- and intralaboratory validation and evaluated the new 4-channel risk-stratified ScreenFire assay in a hierarchal fashion.<br />Results: Both AmpFire and ScreenFire detected 106 (98.1%) of 108 cases with CIN2 or higher, with specificities of 56.7% and 58.1%, respectively. Intralaboratory concordance for 2 runs of AmpFire and ScreenFire was 95.13% and 96.03%, respectively, for overall hrHPV types and 99.10% and 99.46%, respectively, for HPV 16. The interlaboratory concordance of AmpFire and ScreenFire was 93.68% and 94.04% for overall hrHPV and 98.92% and 99.28%, respectively, for HPV 16. Other genotype correlation percentages were similarly high, with κs ranging from 0.86 to 0.94. The ScreenFire RS assay demonstrated excellent "genotype-specific concordance" when evaluated for "clinical guidance" in a hierarchal fashion (noting only the highest risk channel) with both the cobas 4800 and SeqHPV for less than CIN2, CIN2, and CIN3 or higher.<br />Conclusions: The excellent intra- and interlaboratory reproducibility and the established clinical performance, together with the platforms' simplicity, make these assays particularly applicable to low-resource settings.<br /> (© The Author(s) 2024. Published by Oxford University Press on behalf of American Society for Clinical Pathology. All rights reserved. For commercial re-use, please contact reprints@oup.com for reprints and translation rights for reprints. All other permissions can be obtained through our RightsLink service via the Permissions link on the article page on our site—for further information please contact journals.permissions@oup.com.)

Details

Language :
English
ISSN :
1943-7722
Volume :
161
Issue :
6
Database :
MEDLINE
Journal :
American journal of clinical pathology
Publication Type :
Academic Journal
Accession number :
38365314
Full Text :
https://doi.org/10.1093/ajcp/aqad181