Back to Search Start Over

Quantification of Skeletal Muscle Perfusion in Peripheral Artery Disease Using 18 F-Sodium Fluoride Positron Emission Tomography Imaging.

Authors :
Chou TH
Nabavinia M
Tram NK
Rimmerman ET
Patel S
Musini KN
Eisert SN
Wolfe T
Wynveen MK
Matsuzaki Y
Kitsuka T
Iwaki R
Janse SA
Bobbey AJ
Breuer CK
Goodchild L
Malbrue R
Shinoka T
Atway SA
Go MR
Stacy MR
Source :
Journal of the American Heart Association [J Am Heart Assoc] 2024 Feb 20; Vol. 13 (4), pp. e031823. Date of Electronic Publication: 2024 Feb 14.
Publication Year :
2024

Abstract

Background: Perfusion deficits contribute to symptom severity, morbidity, and death in peripheral artery disease (PAD); however, no standard method for quantifying absolute measures of skeletal muscle perfusion exists. This study sought to preclinically test and clinically translate a positron emission tomography (PET) imaging approach using an atherosclerosis-targeted radionuclide, fluorine-18-sodium fluoride ( <superscript>18</superscript> F-NaF), to quantify absolute perfusion in PAD.<br />Methods and Results: Eight Yorkshire pigs underwent unilateral femoral artery ligation and dynamic <superscript>18</superscript> F-NaF PET/computed tomography imaging on the day of and 2 weeks after occlusion. Following 2-week imaging, calf muscles were harvested to quantify microvascular density. PET methodology was validated with microspheres in 4 additional pig studies and translated to patients with PAD (n=39) to quantify differences in calf perfusion across clinical symptoms/stages and perfusion responses in a case of revascularization. Associations between PET perfusion, ankle-brachial index, toe-brachial index, and toe pressure were assessed in relation to symptoms. <superscript>18</superscript> F-NaF PET/computed tomography quantified significant deficits in calf perfusion in pigs following arterial occlusion and perfusion recovery 2 weeks after occlusion that coincided with increased muscle microvascular density. Additional studies confirmed that PET-derived perfusion measures agreed with microsphere-derived perfusion measures. Translation of imaging methods demonstrated significant decreases in calf perfusion with increasing severity of PAD and quantified perfusion responses to revascularization. Perfusion measures were also significantly associated with symptom severity, whereas traditional hemodynamic measures were not.<br />Conclusions: <superscript>18</superscript> F-NaF PET imaging quantifies perfusion deficits that correspond to clinical stages of PAD and represents a novel perfusion imaging strategy that could be partnered with atherosclerosis-targeted <superscript>18</superscript> F-NaF PET imaging using a single radioisotope injection.<br />Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03622359.

Details

Language :
English
ISSN :
2047-9980
Volume :
13
Issue :
4
Database :
MEDLINE
Journal :
Journal of the American Heart Association
Publication Type :
Academic Journal
Accession number :
38353265
Full Text :
https://doi.org/10.1161/JAHA.123.031823