Back to Search Start Over

68 Ga-Pentixafor PET/CT for In Vivo Imaging of CXCR4 Receptors in Glioma Demonstrating a Potential for Response Assessment to Radiochemotherapy: Preliminary Results.

Authors :
Waheed A
Singh B
Watts A
Kaur H
Singh H
Dhingra K
Ahuja C
Madan R
Singh A
Radotra BD
Source :
Clinical nuclear medicine [Clin Nucl Med] 2024 Apr 01; Vol. 49 (4), pp. e141-e148. Date of Electronic Publication: 2024 Feb 01.
Publication Year :
2024

Abstract

Purpose: The aim of this study was to evaluate the diagnostic potential of 68 Ga-pentixafor PET/CT for in vivo CXCR4 receptors imaging in glioma and its possible role in response assessment to radiochemotherapy (R-CT).<br />Methods: Nineteen (12 men, 7 women) patients with glioblastoma multiforme (GBM) underwent 68 Ga-pentixafor PET/CT, contrast-enhanced MR, and MR spectroscopy. Patients were divided in to 2 groups, that is, group I was the presurgical (n = 9) group in which the scanning was done before surgery, and PET findings were correlated with CXCR4 receptors' density. The group II was the postsurgical (n = 10) group in which the scanning was done before and after R-CT and used for treatment response evaluation. The quantitative analysis of 68 Ga-pentixafor PET/CT evaluated the mean SUV max , SUV mean , SUV peak , and T/B values. MR spectroscopy data evaluated the ratios of tumor metabolites (choline, NAA, creatine).<br />Results: 68 Ga-Pentixafor uptake was noted in all (n = 19) the patients. In the group I, the mean SUV max , SUV mean , SUV peak , and T/B values were found to be 4.5 ± 1.6, 0.60 ± 0.26, 1.95 ± 0.8, and 6.9 ± 4.6, respectively. A significant correlation ( P < 0.005) was found between SUV mean and choline/NAA ratio. Immunohistochemistry performed in 7/9 showed CXCR4 receptors' positivity (intensity 3 + ; stained cells >50.0%). In the group II, the mean SUV max at baseline was 4.6 ± 2.1 and did not differ (4.4 ± 1.6) significantly from the value noted at post-R-CT follow-up PET/CT imaging. At 6 months' clinical follow-up, 4 patients showed stable disease. SUV max and T/B ratios at follow-up imaging were lower (3.70 ± 0.90, 2.64 ± 1.35) than the corresponding values (4.40 ± 2.8; 2.91 ± 0.93) noted at baseline. Six (6/10) patients showed disease progression, and the mean SUV max , and T/B ratio in these patients were significantly ( P < 0.05) higher than the corresponding values at baseline and also higher than that noted in the stable patients.<br />Conclusions: 68 Ga-Pentixafor PET/CT can be used for in vivo mapping of CXCR4 receptors in GBM. The technique after validation in a large cohort of patients may have added diagnostic value for the early detection of GBM recurrence and for treatment response evaluation.<br />Competing Interests: Conflicts of interest and sources of funding: none declared. The project was funded by DST-FIST (grant SR/FST/LSI-548/2012), Government of India, New Delhi. No other potential conflicts of interest and funding relevant to this article exist for any author of the article.<br /> (Copyright © 2024 Wolters Kluwer Health, Inc. All rights reserved.)

Details

Language :
English
ISSN :
1536-0229
Volume :
49
Issue :
4
Database :
MEDLINE
Journal :
Clinical nuclear medicine
Publication Type :
Academic Journal
Accession number :
38350065
Full Text :
https://doi.org/10.1097/RLU.0000000000005073